Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-11 22:56 to 2021-07-12 00:45 UTC
Where: 13° 33.3' S 105° 21.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
24 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 28.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 3.6 | 202.36 | 33.991 | 0.03 | 28.20 | 0.02 | < 0.02 | < 0.02 | 1.90 |
21 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 28.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 50.4 | 202.36 | 33.992 | 0.03 | 28.10 | 0.03 | < 0.02 | < 0.02 | 1.83 |
18 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 26.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 26.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 80.8 | 186.68 | 34.505 | 0.68 | 26.84 | 0.21 | 0.05 | 0.09 | 3.75 |
15 | 201.6 | 114.96 | 34.560 | 19.33 | 16.36 | 1.38 | < 0.02 | < 0.02 | 25.54 |
16 | 201.7 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 300.9 | 95.71 | 34.645 | 26.15 | 12.44 | 1.84 | < 0.02 | < 0.02 | 36.20 |
11 | 500.9 | 144.57 | 34.700 | 26.31 | 9.31 | 1.82 | < 0.02 | < 0.02 | 29.56 |
13 | 501 | < 0.02 | < 0.02 | < 0.02 | 9.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 501 | < 0.02 | < 0.02 | < 0.02 | 9.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 751 | 86.69 | 34.661 | 36.43 | 6.69 | 2.61 | < 0.02 | < 0.02 | 71.40 |
7 | 1001 | 89.99 | 34.630 | 37.53 | 5.28 | 2.71 | < 0.02 | < 0.02 | 96.93 |
8 | 1001.1 | < 0.02 | < 0.02 | < 0.02 | 5.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 1001.2 | < 0.02 | < 0.02 | < 0.02 | 5.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1500.1 | 112.64 | 34.671 | 37.47 | 3.67 | 2.71 | < 0.02 | < 0.02 | 114.00 |
5 | 2000.8 | < 0.02 | < 0.02 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2000.8 | 145.55 | 34.729 | 36.31 | 2.46 | 2.58 | < 0.02 | < 0.02 | 122.68 |
1 | 2274.9 | 156.72 | 34.729 | 35.71 | 2.07 | 2.53 | < 0.02 | < 0.02 | 125.48 |
2 | 2275.1 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2275.3 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |