Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-10 14:56 to 2021-07-10 16:51 UTC
Where: 12° 48.1' S 107° 01.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
28 | 2.4 | < 0.02 | < 0.02 | < 0.02 | 27.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 2.6 | 201.91 | 34.083 | 0.13 | 27.43 | 0.10 | 0.03 | 0.03 | 2.78 |
29 | 2.6 | < 0.02 | < 0.02 | < 0.02 | 27.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 27.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 27.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 27.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 50.3 | 201.82 | 34.083 | 0.13 | 27.45 | 0.10 | 0.02 | 0.03 | 2.75 |
22 | 60 | < 0.02 | < 0.02 | < 0.02 | 27.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 60 | < 0.02 | < 0.02 | < 0.02 | 27.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 60 | 203.07 | 34.083 | 0.12 | 27.45 | 0.09 | < 0.02 | 0.03 | 2.73 |
20 | 200.2 | < 0.02 | < 0.02 | < 0.02 | 18.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 200.2 | 118.93 | 34.509 | 17.02 | 18.21 | 1.21 | < 0.02 | < 0.02 | 21.89 |
18 | 300.2 | 110.54 | 34.575 | 23.72 | 12.82 | 1.69 | < 0.02 | < 0.02 | 35.26 |
15 | 499.9 | 98.34 | 34.667 | 30.73 | 9.22 | 2.13 | < 0.02 | < 0.02 | 46.04 |
17 | 500 | < 0.02 | < 0.02 | < 0.02 | 9.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 500.1 | < 0.02 | < 0.02 | < 0.02 | 9.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 750 | 82.44 | < 0.02 | 35.98 | 6.88 | 2.56 | < 0.02 | < 0.02 | 76.36 |
13 | 1000.5 | < 0.02 | < 0.02 | < 0.02 | 5.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1000.5 | < 0.02 | < 0.02 | < 0.02 | 5.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 1000.8 | 93.16 | 34.621 | 37.04 | 5.35 | 2.66 | < 0.02 | < 0.02 | 99.43 |
10 | 1500.9 | 115.85 | 34.677 | 37.41 | 3.61 | 2.68 | < 0.02 | < 0.02 | 115.77 |
9 | 1751.3 | 128.45 | 34.719 | 36.93 | 3.06 | 2.64 | < 0.02 | < 0.02 | 120.11 |
7 | 2001.1 | 140.55 | 34.733 | 36.43 | 2.65 | 2.58 | < 0.02 | < 0.02 | 122.17 |
8 | 2001.2 | < 0.02 | < 0.02 | < 0.02 | 2.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2500.8 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2500.8 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2501.1 | 163.10 | 34.730 | 35.44 | 1.94 | 2.49 | < 0.02 | < 0.02 | 128.89 |
2 | 2720.9 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2720.9 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2721.1 | 165.11 | 34.729 | 35.33 | 1.86 | 2.48 | < 0.02 | < 0.02 | 130.19 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |