Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-08 15:54 to 2021-07-08 17:10 UTC
Where: 10° 33.2' S 105° 32.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
26 | 3 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 3.9 | 201.64 | 33.765 | 0.03 | 28.42 | < 0.02 | < 0.02 | < 0.02 | 1.92 |
24 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 49.8 | 200.48 | 33.953 | 0.02 | 28.31 | 0.04 | < 0.02 | < 0.02 | 1.87 |
22 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 28.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 81.1 | < 0.02 | < 0.02 | < 0.02 | 27.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 81.2 | 181.77 | < 0.02 | 1.12 | 27.06 | 0.23 | 0.02 | 0.16 | 3.47 |
20 | 81.4 | < 0.02 | < 0.02 | < 0.02 | 27.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 199 | 109.46 | 34.557 | 22.46 | 14.01 | 1.57 | < 0.02 | < 0.02 | 32.11 |
17 | 199.1 | < 0.02 | < 0.02 | < 0.02 | 14.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 300 | 90.08 | 34.634 | 28.83 | 10.86 | 1.99 | < 0.02 | < 0.02 | 42.25 |
14 | 400.9 | 85.12 | < 0.02 | 30.99 | 9.87 | 2.12 | < 0.02 | < 0.02 | 44.26 |
12 | 501.1 | < 0.02 | < 0.02 | < 0.02 | 8.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 501.2 | 78.02 | 34.718 | 33.41 | 8.85 | 2.30 | < 0.02 | < 0.02 | 50.18 |
13 | 501.2 | < 0.02 | < 0.02 | < 0.02 | 8.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 599.6 | 74.49 | 34.693 | 35.63 | 7.64 | 2.50 | < 0.02 | < 0.02 | 65.94 |
9 | 699.2 | < 0.02 | < 0.02 | 36.37 | 6.96 | 2.57 | < 0.02 | < 0.02 | 75.48 |
8 | 800.7 | 81.02 | 34.658 | 36.75 | 6.24 | 2.63 | < 0.02 | < 0.02 | 86.33 |
5 | 999.8 | 91.82 | 34.635 | < 0.02 | 5.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 999.9 | < 0.02 | < 0.02 | < 0.02 | 5.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1000 | < 0.02 | < 0.02 | < 0.02 | 5.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1250 | 101.07 | 34.658 | 37.50 | 4.21 | 2.70 | < 0.02 | < 0.02 | 112.45 |
1 | 1470 | 111.97 | 34.700 | 37.25 | 3.59 | 2.68 | < 0.02 | < 0.02 | 116.28 |
2 | 1470.1 | < 0.02 | < 0.02 | < 0.02 | 3.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1470.2 | < 0.02 | < 0.02 | < 0.02 | 3.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |