Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-08 04:21 to 2021-07-08 05:24 UTC
Where: 10° 25.8' S 105° 34.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
22 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 28.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 28.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 3.9 | 201.02 | 33.749 | < 0.02 | 28.55 | 0.02 | < 0.02 | < 0.02 | 1.92 |
19 | 50.6 | 200.53 | 33.782 | < 0.02 | 28.48 | 0.02 | < 0.02 | < 0.02 | 1.95 |
18 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 28.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 28.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 81 | < 0.02 | < 0.02 | < 0.02 | 26.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 81 | 166.76 | 34.602 | 3.26 | 26.06 | 0.41 | < 0.02 | 0.18 | 5.44 |
15 | 81 | < 0.02 | < 0.02 | < 0.02 | 26.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 81 | < 0.02 | < 0.02 | < 0.02 | 26.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 13.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 13.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 200.5 | 113.84 | 34.530 | 22.35 | 13.90 | 1.59 | < 0.02 | < 0.02 | 32.28 |
8 | 350.7 | 91.64 | 34.622 | 30.44 | 9.85 | 2.13 | < 0.02 | < 0.02 | 47.22 |
9 | 350.8 | < 0.02 | < 0.02 | < 0.02 | 9.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 500 | 78.07 | 34.714 | 33.76 | 8.64 | 2.35 | < 0.02 | < 0.02 | 51.89 |
6 | 500.1 | < 0.02 | < 0.02 | < 0.02 | 8.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 500.2 | < 0.02 | < 0.02 | < 0.02 | 8.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 651.1 | 77.08 | 34.683 | 36.08 | 7.16 | 2.58 | < 0.02 | < 0.02 | 72.51 |
1 | 823.2 | 83.43 | 34.649 | 36.56 | 6.10 | 2.65 | < 0.02 | < 0.02 | 87.08 |
3 | 823.4 | < 0.02 | < 0.02 | < 0.02 | 6.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 823.4 | < 0.02 | < 0.02 | < 0.02 | 6.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |