Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-07 09:38 to 2021-07-07 10:48 UTC
Where: 10° 26.2' S 105° 35.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
26 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 28.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 5 | 202.54 | 33.694 | 0.03 | 28.63 | < 0.02 | < 0.02 | < 0.02 | 1.93 |
34 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 28.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 28.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 50.5 | 202.05 | 33.788 | < 0.02 | 28.45 | 0.03 | < 0.02 | < 0.02 | 1.90 |
19 | 90.3 | 181.10 | 34.594 | 0.84 | 26.86 | 0.27 | < 0.02 | 0.14 | 3.75 |
20 | 90.4 | < 0.02 | < 0.02 | < 0.02 | 26.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 90.4 | < 0.02 | < 0.02 | < 0.02 | 26.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 199.9 | 113.84 | 34.531 | 22.08 | 14.07 | 1.57 | < 0.02 | < 0.02 | 31.84 |
18 | 199.9 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 300.9 | 90.08 | 34.633 | 28.76 | 10.87 | 2.01 | < 0.02 | < 0.02 | 41.90 |
15 | 350 | 90.17 | 34.632 | 31.11 | 9.42 | 2.18 | < 0.02 | < 0.02 | 49.09 |
14 | 400.1 | 83.83 | 34.689 | 32.32 | 9.08 | 2.25 | < 0.02 | < 0.02 | 48.35 |
13 | 500.2 | < 0.02 | < 0.02 | < 0.02 | 8.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 500.2 | < 0.02 | 34.715 | 34.15 | 8.46 | 2.40 | < 0.02 | < 0.02 | 54.02 |
12 | 500.2 | < 0.02 | < 0.02 | < 0.02 | 8.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 600.9 | 74.76 | 34.691 | 35.67 | 7.50 | 2.55 | < 0.02 | < 0.02 | 67.67 |
9 | 700.7 | 76.64 | 34.675 | 36.20 | 6.90 | 2.60 | < 0.02 | < 0.02 | 75.83 |
8 | 801 | < 0.02 | < 0.02 | 36.65 | 6.19 | 2.65 | < 0.02 | < 0.02 | 86.73 |
7 | 900.8 | 88.70 | 34.632 | 36.92 | 5.53 | 2.67 | < 0.02 | < 0.02 | 95.36 |
6 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1000.1 | < 0.02 | < 0.02 | < 0.02 | 5.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1000.1 | 92.58 | 34.633 | 37.05 | 5.18 | 2.69 | < 0.02 | < 0.02 | 100.57 |
3 | 1084.9 | < 0.02 | < 0.02 | < 0.02 | 4.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1084.9 | < 0.02 | < 0.02 | < 0.02 | 4.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1084.9 | 93.16 | 34.635 | 37.21 | 4.88 | 2.70 | < 0.02 | < 0.02 | 104.20 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |