Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-06 15:08 to 2021-07-06 17:27 UTC
Where: 10° 34.0' S 105° 45.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
29 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 6 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6.9 | 202.18 | 33.680 | 0.03 | 28.52 | < 0.02 | < 0.02 | < 0.02 | 1.90 |
27 | 7 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 28.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 7.9 | < 0.02 | < 0.02 | < 0.02 | 28.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 50.2 | 201.42 | 33.966 | 0.03 | 28.37 | 0.03 | < 0.02 | < 0.02 | 1.83 |
25 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 28.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 85.6 | < 0.02 | < 0.02 | < 0.02 | 26.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 85.9 | < 0.02 | < 0.02 | < 0.02 | 26.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 86.2 | 176.10 | 34.598 | 1.20 | 26.45 | 0.29 | < 0.02 | 0.20 | 4.21 |
19 | 201.7 | 116.16 | 34.525 | 21.09 | 14.72 | 1.49 | < 0.02 | < 0.02 | 29.75 |
20 | 201.8 | < 0.02 | < 0.02 | < 0.02 | 14.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 301.2 | 86.78 | 34.657 | 29.03 | 11.00 | 2.01 | < 0.02 | < 0.02 | 40.76 |
16 | 502.6 | < 0.02 | < 0.02 | < 0.02 | 8.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 502.6 | 77.62 | 34.736 | 34.25 | 8.56 | 2.38 | < 0.02 | < 0.02 | 52.21 |
17 | 502.7 | < 0.02 | < 0.02 | < 0.02 | 8.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 750.8 | 82.04 | 34.669 | 36.72 | 6.57 | 2.63 | < 0.02 | < 0.02 | 80.85 |
11 | 1002.2 | 90.71 | 34.631 | 37.24 | 5.23 | 2.69 | < 0.02 | < 0.02 | 99.56 |
13 | 1002.4 | < 0.02 | < 0.02 | < 0.02 | 5.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1002.4 | < 0.02 | < 0.02 | < 0.02 | 5.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 1501.1 | 112.28 | 34.705 | 37.45 | 3.58 | 2.70 | < 0.02 | < 0.02 | 115.49 |
9 | 1751.1 | 130.50 | 34.733 | 36.73 | 2.89 | 2.64 | < 0.02 | < 0.02 | 119.05 |
7 | 2001.3 | 144.48 | 34.737 | 36.15 | 2.44 | 2.58 | < 0.02 | < 0.02 | 122.12 |
8 | 2001.5 | < 0.02 | < 0.02 | < 0.02 | 2.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2499.1 | 160.87 | 34.733 | 35.46 | 1.98 | 2.50 | < 0.02 | < 0.02 | 126.45 |
6 | 2499.2 | < 0.02 | < 0.02 | < 0.02 | 1.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2499.2 | < 0.02 | < 0.02 | < 0.02 | 1.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3289.7 | < 0.02 | < 0.02 | < 0.02 | 1.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3289.8 | < 0.02 | < 0.02 | < 0.02 | 1.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3290 | 178.60 | 34.721 | 34.89 | 1.48 | 2.44 | < 0.02 | < 0.02 | 131.89 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |