Deployment Details
Survey: - IN2021_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: CDOM CTD 25 - SN 4367,CTD 25 - SN 1354,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 22-SN 3908,Optode Dissolved Oxygen Concentration,Pressure CTD 25,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 25 - Wetlabs ECO,ThermoSalinoGraph (TSG)-SN 3470,Transmissometer,VMP Microstructure profiler
When: 2021-07-06 11:53 to 2021-07-06 12:41 UTC
Where: 10° 34.8' S 105° 41.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
19 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 3.5 | 207.50 | 33.773 | 0.04 | 28.43 | 0.02 | < 0.02 | < 0.02 | 1.87 |
34 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 4 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 5 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 28.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 28.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 51 | 205.84 | 33.977 | 0.04 | 28.28 | 0.05 | < 0.02 | < 0.02 | 1.92 |
14 | 89.9 | < 0.02 | < 0.02 | < 0.02 | 26.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 90.1 | < 0.02 | < 0.02 | < 0.02 | 26.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 90.1 | 171.72 | 34.605 | 1.83 | 26.38 | 0.35 | < 0.02 | 0.22 | 4.42 |
12 | 201.2 | < 0.02 | < 0.02 | < 0.02 | 14.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 201.3 | 114.38 | 34.530 | 21.75 | 14.37 | 1.54 | < 0.02 | < 0.02 | 30.93 |
10 | 301.1 | 87.85 | 34.641 | 28.64 | 11.17 | 2.00 | < 0.02 | < 0.02 | 40.66 |
9 | 400 | 80.84 | 34.725 | 32.10 | 9.53 | 2.20 | < 0.02 | < 0.02 | 44.01 |
6 | 500.6 | 76.59 | 34.710 | 34.16 | 8.56 | 2.38 | < 0.02 | < 0.02 | 53.65 |
8 | 500.6 | < 0.02 | < 0.02 | < 0.02 | 8.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 500.8 | < 0.02 | < 0.02 | < 0.02 | 8.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 600.4 | 75.08 | 34.687 | 35.52 | 7.65 | 2.52 | 0.02 | < 0.02 | 65.87 |
4 | 700.9 | 76.82 | 34.669 | 36.53 | 6.80 | 2.61 | < 0.02 | < 0.02 | 77.83 |
1 | 800.1 | 80.84 | 34.659 | 36.81 | 6.27 | 2.64 | < 0.02 | < 0.02 | 85.01 |
3 | 800.3 | < 0.02 | < 0.02 | < 0.02 | 6.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 800.4 | < 0.02 | < 0.02 | < 0.02 | 6.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
ThermoSalinoGraph (TSG)-SN 3470 | Seabird | SBE 21 | 3470 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) | ||
VMP Microstructure profiler | Temperature (deg C) |