Deployment Details
Survey: - IN2020_V10 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 24 - SN 1332,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,Transmissometer - CTD 24 -CST-1735DR
When: 2020-11-17 00:12 to 2020-11-17 01:06 UTC
Where: 43° 29.1' S 148° 00.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2018 | 5.2 | < 0.02 | 35.172 | 0.32 | 14.30 | 0.16 | 0.02 | 0.05 | 0.53 |
2019 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 14.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 10.9 | < 0.02 | < 0.02 | 0.32 | 14.29 | 0.16 | 0.02 | 0.05 | 0.56 |
2015 | 20.6 | 271.23 | 35.171 | 0.34 | 14.27 | 0.16 | 0.03 | 0.06 | 0.53 |
2016 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 14.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2014 | 30 | < 0.02 | < 0.02 | 0.46 | 14.08 | 0.17 | 0.09 | 0.07 | 0.55 |
2013 | 40.3 | < 0.02 | < 0.02 | < 0.02 | 13.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 40.6 | 271.14 | 35.147 | 0.94 | 13.76 | 0.21 | 0.18 | 0.11 | 0.60 |
2011 | 50.7 | < 0.02 | < 0.02 | 1.53 | 13.54 | 0.25 | 0.22 | 0.15 | 0.70 |
2010 | 60.3 | < 0.02 | < 0.02 | 1.98 | 13.39 | 0.28 | 0.24 | 0.17 | 0.81 |
2009 | 80.1 | < 0.02 | < 0.02 | 3.73 | 12.83 | 0.40 | 0.25 | 0.22 | 1.20 |
2008 | 100.4 | 264.08 | 35.145 | 5.61 | 12.33 | 0.51 | 0.18 | 0.26 | 1.62 |
1201 | 125.8 | < 0.02 | < 0.02 | 6.24 | 12.18 | 0.54 | 0.13 | 0.26 | 1.78 |
2006 | 150.6 | 262.65 | 35.141 | 6.53 | 12.11 | 0.56 | 0.10 | 0.25 | 1.90 |
2037 | 175.7 | < 0.02 | < 0.02 | 6.39 | 12.15 | 0.56 | 0.12 | 0.25 | 1.84 |
12004 | 200.6 | 262.52 | < 0.02 | 6.57 | 12.12 | 0.57 | 0.10 | 0.25 | 1.89 |
12003 | 230.7 | < 0.02 | < 0.02 | 7.26 | 11.97 | 0.60 | 0.04 | 0.23 | 2.08 |
12002 | 260.7 | 261.94 | 35.130 | 7.48 | 11.87 | 0.62 | 0.02 | 0.21 | 2.15 |
12001 | 260.8 | < 0.02 | < 0.02 | < 0.02 | 11.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |