Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 77
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,Transmissometer - CTD 24 -CST-1735DR
When: 2021-01-06 11:07 to 2021-01-06 12:17 UTC
Where: 57° 55.9' S 141° 31.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
33 | 9.5 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 9.7 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 9.7 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 9.7 | 24.98 | 3.36 | 1.60 | 0.12 | 0.24 | 0.74 |
35 | 9.8 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 9.9 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 10.1 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 10.4 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 10.4 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 10.6 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 10.9 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 11 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 20.2 | 24.96 | 3.36 | 1.59 | 0.10 | 0.24 | 0.70 |
23 | 31.3 | 25.02 | 3.36 | 1.60 | 0.11 | 0.24 | 0.70 |
22 | 41.2 | 25.03 | 3.36 | 1.61 | 0.12 | 0.24 | 0.66 |
21 | 48.6 | 24.98 | 3.36 | 1.60 | 0.10 | 0.24 | 0.63 |
20 | 60.8 | 25.00 | 3.34 | 1.62 | 0.13 | 0.24 | 0.70 |
19 | 69.3 | 25.19 | 3.10 | 1.65 | 0.29 | 0.24 | 1.39 |
18 | 80 | 25.63 | 2.80 | 1.74 | 1.31 | 0.23 | 3.07 |
17 | 90.9 | 25.99 | 2.50 | 1.82 | 0.87 | 0.23 | 5.37 |
16 | 100.7 | 26.25 | 2.20 | 1.85 | 0.96 | 0.23 | 7.13 |
15 | 109 | 26.45 | 2.13 | 1.86 | 0.92 | 0.22 | 8.02 |
14 | 120 | 26.79 | 1.91 | 1.90 | 0.90 | 0.22 | 9.79 |
13 | 130.8 | 27.44 | 1.64 | 1.95 | 0.81 | 0.21 | 12.07 |
12 | 140.4 | 27.74 | 1.53 | 1.95 | 0.68 | 0.22 | 13.10 |
11 | 150.7 | 27.89 | 1.43 | 1.95 | 0.62 | 0.22 | 13.55 |
10 | 160.5 | 28.16 | 1.34 | 1.96 | 0.50 | 0.23 | 14.19 |
9 | 169.3 | 28.33 | 1.25 | 1.96 | 0.46 | 0.22 | 15.04 |
8 | 179.8 | 28.73 | 1.14 | 1.99 | 0.36 | 0.19 | 16.58 |
7 | 190 | 29.16 | 1.04 | 2.00 | 0.21 | 0.15 | 17.69 |
6 | 199.6 | 29.64 | 1.02 | 2.03 | 0.05 | 0.11 | 18.94 |
5 | 210.7 | 29.97 | 1.04 | 2.04 | < 0.02 | 0.07 | 20.01 |
4 | 350.9 | 34.87 | 2.39 | 2.36 | < 0.02 | < 0.02 | 46.75 |
3 | 500.2 | 36.15 | 2.52 | 2.46 | < 0.02 | < 0.02 | 60.56 |
2 | 751.4 | 35.60 | 2.48 | 2.43 | < 0.02 | < 0.02 | 72.91 |
1 | 1000.9 | 34.31 | 2.36 | 2.34 | < 0.02 | < 0.02 | 78.05 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |