Please login if you have access to particular applications.
Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 76
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2021-01-06 01:47 to 2021-01-06 02:57 UTC
Where: 57° 58.6' S 141° 32.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 10.9 | < 0.02 | < 0.02 | < 0.02 | 3.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 11 | < 0.02 | < 0.02 | < 0.02 | 3.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 11.1 | < 0.02 | < 0.02 | < 0.02 | 3.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 11.2 | 335.72 | 33.795 | 24.99 | 3.33 | 1.60 | 0.13 | 0.24 | 0.75 |
| 32 | 20.3 | < 0.02 | < 0.02 | 25.01 | 3.32 | 1.60 | 0.12 | 0.24 | 0.74 |
| 31 | 25.3 | < 0.02 | < 0.02 | < 0.02 | 3.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 25.7 | < 0.02 | < 0.02 | 24.99 | 3.32 | 1.60 | 0.12 | 0.24 | 0.79 |
| 29 | 32.8 | < 0.02 | < 0.02 | < 0.02 | 3.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 39.5 | < 0.02 | < 0.02 | 24.99 | 3.32 | 1.61 | 0.14 | 0.24 | 0.77 |
| 26 | 49.8 | 335.23 | 33.795 | 25.00 | 3.32 | 1.60 | 0.12 | 0.24 | 0.75 |
| 27 | 49.8 | < 0.02 | < 0.02 | < 0.02 | 3.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.6 | < 0.02 | < 0.02 | 24.96 | 3.31 | 1.62 | 0.18 | 0.24 | 0.78 |
| 24 | 70.9 | < 0.02 | < 0.02 | < 0.02 | 3.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 75.6 | < 0.02 | < 0.02 | 25.25 | 3.04 | 1.67 | 0.38 | 0.24 | 1.82 |
| 21 | 80.8 | 335.49 | 33.819 | 25.73 | 2.59 | 1.78 | 0.84 | 0.23 | 4.15 |
| 22 | 81 | < 0.02 | < 0.02 | < 0.02 | 2.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 90.6 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 101.3 | < 0.02 | < 0.02 | < 0.02 | 2.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 101.8 | 335.58 | 33.828 | 26.16 | 2.21 | 1.84 | 0.95 | 0.23 | 7.08 |
| 17 | 120.6 | < 0.02 | < 0.02 | < 0.02 | 1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 126.3 | < 0.02 | < 0.02 | 27.34 | 1.68 | 1.95 | 0.84 | 0.22 | 11.69 |
| 14 | 149.8 | 338.84 | 33.851 | 27.78 | 1.42 | 1.95 | 0.67 | 0.21 | 14.39 |
| 15 | 150.3 | < 0.02 | < 0.02 | < 0.02 | 1.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 174.8 | < 0.02 | < 0.02 | 28.41 | 1.23 | 1.96 | 0.44 | 0.22 | 15.44 |
| 11 | 200 | 332.64 | 33.895 | 29.40 | 1.00 | 2.01 | 0.14 | 0.14 | 18.42 |
| 12 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 224.5 | < 0.02 | < 0.02 | 30.25 | 1.15 | 2.06 | < 0.02 | 0.03 | 21.16 |
| 9 | 250.4 | < 0.02 | < 0.02 | 31.82 | 1.69 | 2.16 | < 0.02 | < 0.02 | 28.21 |
| 8 | 301.6 | 254.61 | 34.154 | 33.59 | 2.15 | 2.27 | < 0.02 | < 0.02 | 37.87 |
| 7 | 347.4 | < 0.02 | < 0.02 | 34.52 | 2.30 | 2.33 | < 0.02 | < 0.02 | 44.02 |
| 6 | 399.9 | < 0.02 | < 0.02 | 35.38 | 2.45 | 2.40 | < 0.02 | < 0.02 | 50.68 |
| 5 | 499.4 | 192.80 | 34.392 | 36.20 | 2.51 | 2.46 | < 0.02 | < 0.02 | 60.74 |
| 4 | 601 | 181.37 | 34.469 | 36.37 | 2.52 | 2.47 | < 0.02 | < 0.02 | 67.26 |
| 3 | 750.5 | 176.19 | 34.561 | 35.68 | 2.48 | 2.43 | < 0.02 | < 0.02 | 73.28 |
| 2 | 800.8 | 176.54 | 34.580 | 35.34 | 2.47 | 2.41 | < 0.02 | < 0.02 | 74.24 |
| 1 | 1001.3 | 179.67 | 34.655 | 34.17 | 2.35 | 2.33 | < 0.02 | < 0.02 | 78.33 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
| ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |