Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 53
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-27 09:31 to 2020-12-27 11:19 UTC
Where: 55° 49.0' S 138° 40.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
34 | 8.5 | 326.29 | 33.804 | 24.54 | 4.15 | 1.60 | 0.16 | 0.23 | 3.28 |
36 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 4.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 8.9 | < 0.02 | < 0.02 | < 0.02 | 4.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 40.3 | 327.63 | 33.806 | 24.56 | 4.10 | 1.61 | 0.18 | 0.22 | 3.33 |
32 | 40.4 | < 0.02 | < 0.02 | < 0.02 | 4.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 4.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 70.4 | < 0.02 | < 0.02 | < 0.02 | 3.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 3.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 70.5 | 332.55 | 33.817 | 25.07 | 3.55 | 1.66 | 0.26 | 0.22 | 3.92 |
27 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 3.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 80.7 | 334.02 | 33.822 | 25.41 | 3.09 | 1.71 | 0.37 | 0.22 | 5.23 |
26 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 3.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 110.7 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 110.9 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 110.9 | 326.65 | 33.857 | 27.07 | 2.36 | 1.90 | 0.50 | 0.22 | 13.02 |
20 | 150.3 | < 0.02 | < 0.02 | < 0.02 | 2.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 150.4 | < 0.02 | < 0.02 | < 0.02 | 2.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 150.6 | 320.40 | 33.888 | 28.29 | 2.08 | 1.95 | 0.04 | 0.20 | 15.36 |
16 | 250 | 259.70 | 34.122 | 31.84 | 2.66 | 2.16 | < 0.02 | 0.02 | 31.77 |
17 | 250.3 | < 0.02 | < 0.02 | < 0.02 | 2.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 250.3 | < 0.02 | < 0.02 | < 0.02 | 2.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 500.4 | 195.30 | 34.389 | 35.27 | 2.54 | 2.41 | < 0.02 | < 0.02 | 59.36 |
14 | 500.7 | < 0.02 | < 0.02 | < 0.02 | 2.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 500.9 | < 0.02 | < 0.02 | < 0.02 | 2.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 750.4 | 176.95 | 34.563 | 34.78 | 2.53 | 2.39 | < 0.02 | < 0.02 | 72.03 |
12 | 750.9 | < 0.02 | < 0.02 | < 0.02 | 2.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 751 | < 0.02 | < 0.02 | < 0.02 | 2.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 2.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 2.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1000.9 | 180.52 | 34.657 | 33.39 | 2.38 | 2.29 | < 0.02 | < 0.02 | 77.10 |
6 | 1500.4 | < 0.02 | < 0.02 | < 0.02 | 2.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1500.5 | < 0.02 | < 0.02 | < 0.02 | 2.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1500.6 | 196.20 | 34.740 | 31.28 | 2.04 | 2.15 | < 0.02 | < 0.02 | 84.58 |
3 | 2001 | < 0.02 | < 0.02 | < 0.02 | 1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2001.1 | < 0.02 | < 0.02 | < 0.02 | 1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2001.1 | 204.50 | 34.743 | 31.35 | 1.60 | 2.16 | < 0.02 | < 0.02 | 97.16 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |