Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 47
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-24 19:20 to 2020-12-24 20:40 UTC
Where: 55° 52.1' S 139° 02.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 4.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.8 | 327.41 | 33.810 | 24.80 | 4.04 | 1.65 | 0.19 | 0.22 | 3.74 |
33 | 9.7 | 327.01 | 33.810 | 24.80 | 4.04 | 1.64 | 0.18 | 0.22 | 3.66 |
34 | 10.5 | < 0.02 | < 0.02 | < 0.02 | 4.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 4.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 24.3 | 327.23 | 33.811 | 24.86 | 4.04 | 1.65 | 0.19 | 0.22 | 3.67 |
31 | 25.4 | < 0.02 | < 0.02 | < 0.02 | 4.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 29.8 | < 0.02 | < 0.02 | < 0.02 | 4.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 40 | < 0.02 | < 0.02 | < 0.02 | 4.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 4.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 50.1 | 327.45 | 33.810 | 24.87 | 3.99 | 1.64 | 0.20 | 0.22 | 3.69 |
25 | 60.4 | < 0.02 | < 0.02 | 24.94 | 3.89 | 1.71 | 0.27 | 0.22 | 3.80 |
23 | 70.1 | 330.76 | 33.820 | 25.38 | 3.50 | 1.74 | 0.39 | 0.22 | 5.24 |
24 | 70.1 | < 0.02 | < 0.02 | < 0.02 | 3.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 80.5 | < 0.02 | < 0.02 | 26.03 | 2.88 | 2.25 | 0.75 | 0.21 | 8.15 |
20 | 90.2 | < 0.02 | < 0.02 | < 0.02 | 2.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 90.2 | 326.87 | 33.848 | 26.77 | 2.64 | 1.90 | 0.56 | 0.19 | 11.66 |
19 | 100.5 | < 0.02 | < 0.02 | 27.19 | 2.57 | 1.93 | 0.48 | 0.19 | 13.17 |
18 | 109.8 | < 0.02 | < 0.02 | 27.33 | 2.32 | 1.93 | 0.48 | 0.19 | 13.37 |
17 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 2.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 124.7 | < 0.02 | < 0.02 | 27.91 | 2.20 | 1.94 | 0.28 | 0.18 | 14.74 |
14 | 149.1 | < 0.02 | < 0.02 | 28.29 | 2.01 | 1.96 | 0.24 | 0.17 | 15.91 |
15 | 149.2 | < 0.02 | < 0.02 | < 0.02 | 2.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 175.4 | < 0.02 | < 0.02 | 29.92 | 2.33 | 2.05 | < 0.02 | 0.05 | 22.02 |
12 | 199.5 | < 0.02 | < 0.02 | < 0.02 | 2.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 199.6 | 275.42 | 34.060 | 30.91 | 2.64 | 2.11 | < 0.02 | < 0.02 | 26.59 |
10 | 225.2 | < 0.02 | < 0.02 | 31.67 | 2.67 | 2.17 | < 0.02 | < 0.02 | 30.46 |
9 | 251.1 | < 0.02 | < 0.02 | 32.33 | 2.74 | 2.21 | < 0.02 | < 0.02 | 33.82 |
8 | 300.7 | 236.66 | 34.206 | 33.36 | 2.67 | 2.29 | < 0.02 | < 0.02 | 39.98 |
7 | 350.2 | < 0.02 | < 0.02 | 34.23 | 2.60 | 2.35 | < 0.02 | < 0.02 | 46.09 |
6 | 400.4 | 213.35 | 34.300 | 34.80 | 2.58 | 2.38 | < 0.02 | < 0.02 | 50.69 |
5 | 500.4 | 194.10 | 34.394 | 35.42 | 2.64 | 2.42 | < 0.02 | < 0.02 | 59.09 |
4 | 600.5 | 182.22 | 34.477 | 35.54 | 2.60 | 2.43 | < 0.02 | 0.02 | 66.10 |
3 | 750.3 | 176.95 | 34.566 | 34.95 | 2.52 | 2.40 | < 0.02 | < 0.02 | 72.47 |
2 | 800.6 | 176.77 | 34.588 | 34.67 | 2.52 | 2.38 | < 0.02 | < 0.02 | 73.63 |
1 | 999.8 | 180.65 | 34.655 | 33.59 | 2.38 | 2.31 | < 0.02 | < 0.02 | 77.34 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |