Please login if you have access to particular applications.
Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 26
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-13 21:07 to 2020-12-13 22:37 UTC
Where: 47° 04.9' S 141° 22.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 9.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.8 | 293.20 | 34.528 | 11.36 | 9.74 | 0.85 | 0.14 | 0.24 | 1.14 |
34 | 10.4 | < 0.02 | < 0.02 | 11.38 | 9.73 | 0.85 | 0.13 | 0.24 | 1.17 |
33 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 9.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 25.9 | < 0.02 | < 0.02 | < 0.02 | 9.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 25.9 | 292.84 | 34.527 | 11.39 | 9.72 | 0.85 | 0.14 | 0.24 | 1.17 |
30 | 29.8 | < 0.02 | < 0.02 | < 0.02 | 9.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 40.2 | < 0.02 | < 0.02 | 11.51 | 9.68 | 0.86 | 0.19 | 0.25 | 1.28 |
27 | 50.1 | < 0.02 | < 0.02 | 11.87 | 9.52 | 0.90 | 0.38 | 0.25 | 1.61 |
28 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 9.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 9.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 60.6 | 286.99 | 34.517 | 11.96 | 9.50 | 0.91 | 0.40 | 0.27 | 1.74 |
24 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 9.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 75.2 | < 0.02 | < 0.02 | 11.99 | 9.50 | 0.91 | 0.41 | 0.26 | 1.79 |
22 | 78.6 | < 0.02 | < 0.02 | 11.98 | 9.50 | 0.91 | 0.43 | 0.26 | 1.78 |
21 | 90 | < 0.02 | < 0.02 | < 0.02 | 9.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 100.5 | 285.29 | 34.521 | 12.13 | 9.49 | 0.91 | 0.42 | 0.26 | 1.96 |
20 | 100.8 | < 0.02 | < 0.02 | < 0.02 | 9.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 120.5 | < 0.02 | < 0.02 | < 0.02 | 9.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 125.2 | < 0.02 | < 0.02 | 12.59 | 9.57 | 0.94 | 0.27 | 0.19 | 2.44 |
16 | 149.9 | < 0.02 | < 0.02 | < 0.02 | 9.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 150.1 | < 0.02 | < 0.02 | 12.94 | 9.76 | 0.94 | < 0.02 | 0.03 | 2.90 |
14 | 175.4 | < 0.02 | < 0.02 | 12.81 | 9.82 | 0.93 | < 0.02 | 0.02 | 2.87 |
13 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 9.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 200.5 | 273.10 | 34.760 | 12.64 | 9.90 | 0.92 | < 0.02 | 0.02 | 2.86 |
11 | 225.1 | < 0.02 | < 0.02 | 12.70 | 9.86 | 0.92 | < 0.02 | 0.02 | 2.85 |
10 | 250.6 | < 0.02 | < 0.02 | 12.53 | 9.94 | 0.91 | < 0.02 | < 0.02 | 2.83 |
9 | 300.7 | 273.01 | 34.756 | 12.73 | 9.85 | 0.92 | < 0.02 | < 0.02 | 2.86 |
8 | 350.1 | < 0.02 | < 0.02 | 13.84 | 9.51 | 0.99 | < 0.02 | < 0.02 | 3.19 |
7 | 400.7 | < 0.02 | < 0.02 | < 0.02 | 9.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 400.7 | 259.17 | 34.680 | 15.46 | 9.35 | 1.09 | < 0.02 | < 0.02 | 4.14 |
5 | 500.7 | 256.80 | 34.634 | 17.00 | 9.02 | 1.18 | < 0.02 | < 0.02 | 4.86 |
4 | 600.3 | 251.31 | 34.572 | 18.64 | 8.59 | 1.29 | < 0.02 | < 0.02 | 6.12 |
3 | 750.6 | 222.01 | 34.462 | 23.92 | 7.41 | 1.61 | < 0.02 | < 0.02 | 12.28 |
2 | 800.7 | 214.37 | 34.432 | 25.79 | 6.89 | 1.73 | < 0.02 | < 0.02 | 15.65 |
1 | 1000.6 | 211.83 | 34.348 | 29.63 | 5.19 | 2.00 | < 0.02 | < 0.02 | 26.34 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |