Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-12 10:00 to 2020-12-12 11:28 UTC
Where: 47° 06.6' S 141° 22.6' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
12 | 7.9 | 293.29 | 34.533 | 11.72 | 9.61 | 0.86 | 0.07 | 0.26 | 1.75 |
11 | 39.2 | 289.54 | 34.534 | 11.96 | 9.51 | 0.88 | 0.14 | 0.25 | 1.88 |
10 | 80.2 | 286.59 | 34.538 | 12.06 | 9.51 | 0.90 | 0.27 | 0.25 | 2.05 |
9 | 130.9 | 283.64 | 34.518 | 14.45 | 8.80 | 1.04 | < 0.02 | 0.02 | 3.01 |
8 | 150.5 | 283.95 | 34.519 | 14.43 | 8.78 | 1.04 | < 0.02 | < 0.02 | 2.99 |
7 | 251.8 | 282.44 | 34.530 | 14.53 | 8.79 | 1.05 | < 0.02 | < 0.02 | 3.04 |
6 | 501.5 | 265.20 | 34.628 | 16.39 | 8.98 | 1.15 | < 0.02 | < 0.02 | 4.52 |
5 | 749.8 | 223.66 | 34.472 | 23.49 | 7.58 | 1.59 | < 0.02 | < 0.02 | 11.63 |
4 | 999.2 | 206.33 | 34.379 | 29.55 | 5.41 | 2.01 | < 0.02 | < 0.02 | 27.92 |
3 | 999.4 | 206.07 | 34.379 | 29.57 | 5.40 | 2.01 | < 0.02 | < 0.02 | 27.97 |
2 | 1500.1 | 175.65 | 34.494 | 34.79 | 3.11 | 2.40 | < 0.02 | < 0.02 | 67.01 |
1 | 1999.5 | 175.79 | 34.668 | 33.60 | 2.45 | 2.32 | < 0.02 | < 0.02 | 83.68 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |