Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-11 06:42 to 2020-12-11 10:02 UTC
Where: 47° 06.5' S 141° 23.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 301.2 | < 0.02 | < 0.02 | < 0.02 | 9.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 400 | < 0.02 | < 0.02 | < 0.02 | 9.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 400.3 | 260.82 | 34.652 | 15.85 | 9.22 | 1.12 | < 0.02 | < 0.02 | 4.30 |
33 | 600.5 | 248.09 | 34.562 | 19.16 | 8.52 | 1.33 | < 0.02 | < 0.02 | 6.56 |
32 | 750.2 | < 0.02 | < 0.02 | < 0.02 | 7.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 800.8 | 214.02 | 34.446 | 25.55 | 7.13 | 1.73 | < 0.02 | < 0.02 | 15.22 |
29 | 1001 | < 0.02 | < 0.02 | < 0.02 | 5.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 1001.2 | 215.09 | 34.328 | 30.15 | 5.01 | 2.05 | < 0.02 | < 0.02 | 26.81 |
28 | 1001.2 | < 0.02 | < 0.02 | < 0.02 | 5.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 1001.5 | < 0.02 | < 0.02 | < 0.02 | 5.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 1200.9 | < 0.02 | < 0.02 | < 0.02 | 4.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 1201 | 193.96 | 34.391 | 32.72 | 4.12 | 2.24 | < 0.02 | < 0.02 | 45.11 |
23 | 1401.2 | < 0.02 | < 0.02 | < 0.02 | 3.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 1401.2 | 179.22 | 34.459 | 34.47 | 3.40 | 2.39 | < 0.02 | < 0.02 | 61.50 |
22 | 1600.2 | < 0.02 | < 0.02 | < 0.02 | 2.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 1800.6 | < 0.02 | < 0.02 | < 0.02 | 2.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 2000.2 | < 0.02 | < 0.02 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 2000.4 | 175.38 | 34.664 | 33.78 | 2.47 | 2.34 | < 0.02 | < 0.02 | 83.40 |
18 | 2250.4 | < 0.02 | < 0.02 | < 0.02 | 2.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 2501 | 180.43 | 34.726 | 33.12 | 2.13 | 2.30 | < 0.02 | < 0.02 | 97.94 |
16 | 2501.1 | < 0.02 | < 0.02 | < 0.02 | 2.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 2751 | < 0.02 | < 0.02 | < 0.02 | 1.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 3000.4 | 189.23 | 34.734 | 32.83 | 1.82 | 2.28 | < 0.02 | < 0.02 | 106.66 |
13 | 3000.5 | < 0.02 | < 0.02 | < 0.02 | 1.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 3250.4 | < 0.02 | < 0.02 | < 0.02 | 1.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 3499.9 | < 0.02 | < 0.02 | < 0.02 | 1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 3500 | 197.67 | 34.731 | 32.73 | 1.53 | 2.27 | < 0.02 | < 0.02 | 112.62 |
9 | 3751 | < 0.02 | < 0.02 | < 0.02 | 1.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 4000.2 | < 0.02 | < 0.02 | < 0.02 | 1.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 4000.3 | 204.10 | 34.722 | 32.76 | 1.30 | 2.27 | < 0.02 | < 0.02 | 117.84 |
6 | 4249.6 | < 0.02 | < 0.02 | < 0.02 | 1.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 4500.6 | 207.45 | 34.712 | 33.14 | 1.09 | 2.30 | < 0.02 | < 0.02 | 123.52 |
4 | 4500.7 | < 0.02 | < 0.02 | < 0.02 | 1.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 4711.5 | 207.32 | 34.711 | 33.21 | 1.10 | 2.30 | < 0.02 | < 0.02 | 123.96 |
2 | 4711.7 | < 0.02 | < 0.02 | < 0.02 | 1.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 4711.8 | < 0.02 | < 0.02 | < 0.02 | 1.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |