Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-09 19:42 to 2020-12-09 21:10 UTC
Where: 47° 06.2' S 141° 23.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.1 | 287.44 | 34.537 | 12.00 | 9.54 | 0.91 | 0.21 | 0.27 | 2.05 |
35 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 9.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 10.3 | < 0.02 | < 0.02 | 11.99 | 9.54 | 0.91 | 0.21 | 0.27 | 2.05 |
33 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 9.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 25.5 | < 0.02 | < 0.02 | 11.99 | 9.55 | 0.90 | 0.21 | 0.27 | 2.06 |
31 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 9.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.8 | < 0.02 | < 0.02 | 12.00 | 9.54 | 0.91 | 0.23 | 0.26 | 2.07 |
29 | 50.2 | 287.13 | 34.536 | 11.99 | 9.55 | 0.90 | 0.21 | 0.26 | 2.08 |
28 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 9.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 60.3 | < 0.02 | < 0.02 | 11.98 | 9.55 | 0.91 | 0.22 | 0.26 | 2.08 |
26 | 70.8 | < 0.02 | < 0.02 | < 0.02 | 9.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 75.5 | < 0.02 | < 0.02 | 12.04 | 9.55 | 0.92 | 0.25 | 0.26 | 2.12 |
24 | 80.5 | < 0.02 | < 0.02 | 12.04 | 9.55 | 0.92 | 0.24 | 0.26 | 2.16 |
22 | 90.3 | < 0.02 | < 0.02 | < 0.02 | 9.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 90.6 | 286.23 | 34.543 | 12.10 | 9.55 | 0.91 | 0.23 | 0.26 | 2.21 |
21 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 9.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 110.2 | 281.90 | 34.583 | 13.14 | 9.38 | 0.98 | 0.10 | 0.18 | 2.80 |
19 | 120.7 | < 0.02 | < 0.02 | 13.69 | 9.17 | 1.01 | < 0.02 | 0.15 | 2.91 |
18 | 151.1 | < 0.02 | < 0.02 | 14.15 | 8.97 | 1.04 | < 0.02 | 0.02 | 2.99 |
17 | 151.1 | < 0.02 | < 0.02 | < 0.02 | 8.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 175.4 | < 0.02 | < 0.02 | 13.99 | 9.08 | 1.02 | < 0.02 | 0.02 | 3.02 |
14 | 200.1 | < 0.02 | < 0.02 | < 0.02 | 9.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 200.2 | 276.90 | 34.655 | 13.48 | 9.43 | 0.99 | < 0.02 | < 0.02 | 3.03 |
13 | 224.7 | < 0.02 | < 0.02 | 14.12 | 9.00 | 1.03 | < 0.02 | < 0.02 | 3.08 |
12 | 250.6 | < 0.02 | 34.611 | 13.95 | 9.18 | 1.02 | < 0.02 | 0.02 | 3.08 |
11 | 300.8 | 276.50 | 34.617 | 14.10 | 9.18 | 1.03 | < 0.02 | < 0.02 | 3.21 |
10 | 350.2 | < 0.02 | < 0.02 | 14.60 | 9.29 | 1.06 | < 0.02 | < 0.02 | 3.67 |
9 | 400.8 | 256.93 | 34.688 | 15.82 | 9.37 | 1.13 | < 0.02 | < 0.02 | 4.42 |
7 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 9.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 500.6 | 257.43 | 34.641 | 16.77 | 9.08 | 1.19 | < 0.02 | < 0.02 | 4.87 |
6 | 601 | 256.93 | 34.575 | 18.08 | 8.63 | 1.27 | < 0.02 | < 0.02 | 5.75 |
5 | 750.1 | 221.79 | 34.465 | 23.90 | 7.49 | 1.63 | < 0.02 | < 0.02 | 12.29 |
4 | 800.3 | 214.73 | 34.443 | 25.53 | 7.01 | 1.74 | < 0.02 | < 0.02 | 15.39 |
2 | 1000.8 | < 0.02 | < 0.02 | < 0.02 | 5.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1000.8 | 208.25 | 34.366 | 29.78 | 5.31 | 2.03 | < 0.02 | < 0.02 | 27.49 |
3 | 1000.9 | < 0.02 | < 0.02 | < 0.02 | 5.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |