Deployment Details
Survey: - IN2020_V08 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 24 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer - CTD 24 -CST-1735DR
When: 2020-12-05 04:18 to 2020-12-05 05:45 UTC
Where: 44° 43.5' S 145° 32.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 6.9 | 262.34 | 35.307 | 3.36 | 13.56 | 0.35 | 0.14 | 0.21 | 1.54 |
30 | 10.9 | < 0.02 | < 0.02 | 3.36 | 13.56 | 0.35 | 0.14 | 0.21 | 1.50 |
29 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 25.4 | < 0.02 | < 0.02 | 3.36 | 13.57 | 0.35 | 0.14 | 0.21 | 1.53 |
27 | 30.3 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 40.3 | < 0.02 | < 0.02 | 3.36 | 13.57 | 0.35 | 0.15 | 0.20 | 1.52 |
25 | 50.9 | 262.20 | 35.306 | 3.37 | 13.57 | 0.35 | 0.15 | 0.20 | 1.58 |
24 | 59.1 | < 0.02 | < 0.02 | 3.39 | 13.57 | 0.36 | 0.16 | 0.21 | 1.63 |
23 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 13.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 75.3 | < 0.02 | < 0.02 | 3.40 | 13.57 | 0.36 | 0.18 | 0.20 | 1.59 |
21 | 81.1 | < 0.02 | < 0.02 | 3.42 | 13.57 | 0.36 | 0.21 | 0.21 | 1.60 |
20 | 90.6 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 100.4 | < 0.02 | < 0.02 | 3.65 | 13.53 | 0.37 | 0.25 | 0.21 | 1.65 |
18 | 109 | 256.13 | 35.285 | 4.99 | 13.29 | 0.45 | 0.16 | 0.17 | 1.89 |
17 | 120.7 | < 0.02 | < 0.02 | < 0.02 | 12.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 123.2 | < 0.02 | < 0.02 | 7.48 | 12.68 | 0.59 | < 0.02 | 0.05 | 2.40 |
15 | 130.4 | < 0.02 | < 0.02 | < 0.02 | 12.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 140.5 | < 0.02 | < 0.02 | < 0.02 | 12.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 149.6 | 250.37 | 35.168 | 8.79 | 12.17 | 0.67 | < 0.02 | < 0.02 | 2.70 |
12 | 174.9 | < 0.02 | < 0.02 | 9.27 | 11.87 | 0.70 | < 0.02 | 0.02 | 2.77 |
11 | 201.7 | 250.73 | 35.070 | 10.27 | 11.56 | 0.76 | < 0.02 | < 0.02 | 3.12 |
10 | 226 | < 0.02 | < 0.02 | 10.31 | 11.48 | 0.76 | < 0.02 | < 0.02 | 3.11 |
9 | 250.4 | < 0.02 | < 0.02 | 11.17 | 11.24 | 0.82 | < 0.02 | < 0.02 | 3.34 |
8 | 301.5 | 261.53 | 35.051 | 10.27 | 11.29 | 0.76 | < 0.02 | < 0.02 | 3.02 |
7 | 350.8 | < 0.02 | < 0.02 | 11.96 | 10.90 | 0.87 | < 0.02 | < 0.02 | 3.57 |
6 | 400.7 | 245.41 | 34.888 | 13.92 | 10.41 | 0.98 | < 0.02 | < 0.02 | 4.38 |
5 | 501.5 | 234.29 | 34.769 | 18.81 | 9.03 | 1.28 | < 0.02 | < 0.02 | 6.81 |
4 | 601.5 | 212.81 | 34.563 | 23.03 | 8.06 | 1.53 | < 0.02 | < 0.02 | 12.09 |
3 | 749 | 194.99 | 34.430 | 29.77 | 5.62 | 1.98 | < 0.02 | < 0.02 | 31.49 |
2 | 801 | 193.65 | 34.422 | 30.54 | 5.27 | 2.03 | < 0.02 | < 0.02 | 35.34 |
1 | 1000.9 | 179.00 | 34.461 | 32.94 | 4.31 | 2.21 | < 0.02 | < 0.02 | 53.89 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 3835 | 241 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 24 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |