Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 66
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-12 01:23 to 2021-03-12 02:51 UTC
Where: 65° 14.9' S 80° 00.3' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.3 | 362.29 | 32.918 | 18.83 | -1.14 | 1.26 | 0.40 | 0.28 | 4.91 |
36 | 4.4 | < 0.02 | < 0.02 | < 0.02 | -1.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 14.9 | 350.99 | 33.428 | 20.84 | -0.30 | 1.37 | 0.43 | 0.29 | 6.10 |
33 | 24.6 | 338.89 | 33.652 | 21.62 | 0.17 | 1.54 | 1.11 | 0.29 | 7.91 |
32 | 40.6 | 297.13 | 34.049 | 29.54 | -0.97 | 2.23 | 1.93 | 0.22 | 53.39 |
31 | 40.7 | < 0.02 | < 0.02 | < 0.02 | -0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 54.8 | < 0.02 | < 0.02 | < 0.02 | -1.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 54.9 | 280.38 | 34.209 | 32.18 | -1.26 | 2.28 | 0.65 | 0.24 | 65.73 |
28 | 70.5 | 280.38 | 34.256 | 32.37 | -0.95 | 2.25 | 0.17 | 0.19 | 66.12 |
27 | 90.4 | 273.91 | 34.314 | 32.51 | -0.72 | 2.24 | < 0.02 | 0.08 | 67.86 |
26 | 120 | 297.53 | 34.325 | 31.25 | -1.23 | 2.16 | < 0.02 | 0.04 | 62.46 |
25 | 180.3 | 266.13 | 34.429 | 32.46 | -0.50 | 2.24 | < 0.02 | 0.02 | 71.40 |
24 | 239.6 | 208.25 | 34.576 | 33.93 | 0.93 | 2.34 | < 0.02 | 0.02 | 85.59 |
22 | 301.3 | < 0.02 | < 0.02 | < 0.02 | 1.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 301.7 | 197.71 | 34.640 | 33.70 | 1.29 | 2.33 | < 0.02 | 0.02 | 89.23 |
20 | 350.6 | < 0.02 | < 0.02 | < 0.02 | 1.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 350.9 | 206.69 | 34.645 | 33.22 | 1.13 | 2.30 | < 0.02 | 0.02 | 89.36 |
16 | 499.1 | 203.25 | 34.697 | 32.51 | 1.33 | 2.25 | < 0.02 | 0.02 | 93.06 |
17 | 499.3 | < 0.02 | < 0.02 | < 0.02 | 1.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 499.4 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 499.5 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 600 | 209.28 | 34.696 | 32.37 | 1.17 | 2.24 | < 0.02 | < 0.02 | 94.32 |
14 | 674.9 | 213.88 | 34.693 | 32.28 | 1.04 | 2.23 | < 0.02 | < 0.02 | 95.96 |
12 | 801.5 | 211.87 | 34.707 | 32.27 | 1.05 | 2.24 | < 0.02 | 0.02 | 100.52 |
13 | 802 | < 0.02 | < 0.02 | < 0.02 | 1.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 952.5 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 953.1 | 214.06 | 34.701 | 32.51 | 0.89 | 2.26 | < 0.02 | 0.02 | 105.49 |
8 | 1251 | < 0.02 | < 0.02 | < 0.02 | 0.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 1251.4 | 220.85 | 34.682 | 33.01 | 0.53 | 2.29 | < 0.02 | 0.02 | 112.69 |
7 | 1496.2 | < 0.02 | < 0.02 | < 0.02 | 0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1496.7 | 221.30 | 34.681 | 33.26 | 0.42 | 2.31 | < 0.02 | 0.02 | 119.65 |
5 | 1496.9 | < 0.02 | < 0.02 | < 0.02 | 0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1497.1 | < 0.02 | < 0.02 | < 0.02 | 0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1497.3 | < 0.02 | < 0.02 | < 0.02 | 0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1497.4 | < 0.02 | < 0.02 | < 0.02 | 0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1499.4 | < 0.02 | < 0.02 | < 0.02 | 0.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |