Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 63
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-11 04:58 to 2021-03-11 08:13 UTC
Where: 64° 35.0' S 80° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.9 | 337.41 | 33.725 | 22.73 | 0.65 | 1.49 | 1.20 | 0.30 | 10.55 |
36 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15 | 337.50 | 33.724 | 22.75 | 0.63 | 1.50 | 1.19 | 0.30 | 10.53 |
33 | 35.4 | 336.61 | 33.729 | 22.91 | 0.58 | 1.51 | 1.18 | 0.29 | 10.95 |
31 | 43.9 | < 0.02 | < 0.02 | < 0.02 | -1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 44.1 | 287.26 | 34.114 | 31.29 | -1.01 | 2.30 | 1.40 | 0.21 | 58.74 |
30 | 55.2 | 275.11 | 34.180 | 32.35 | -0.89 | 2.30 | 0.76 | 0.25 | 63.43 |
29 | 55.5 | < 0.02 | < 0.02 | < 0.02 | -0.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 80.5 | 223.97 | 34.376 | 34.84 | 0.42 | 2.40 | < 0.02 | 0.08 | 75.08 |
27 | 120.4 | < 0.02 | < 0.02 | < 0.02 | 1.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 120.5 | 187.80 | 34.528 | 35.72 | 1.41 | 2.45 | < 0.02 | 0.03 | 83.74 |
25 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 200.6 | 174.76 | 34.634 | 35.18 | 1.87 | 2.41 | < 0.02 | 0.03 | 88.60 |
23 | 350.4 | 182.22 | 34.697 | 33.62 | 1.88 | 2.30 | < 0.02 | 0.02 | 90.58 |
22 | 525.3 | 192.27 | 34.728 | 32.44 | 1.78 | 2.22 | < 0.02 | 0.02 | 91.73 |
21 | 750.4 | < 0.02 | < 0.02 | < 0.02 | 1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 750.4 | 200.97 | 34.739 | 31.74 | 1.59 | 2.18 | < 0.02 | 0.02 | 95.21 |
18 | 1050.4 | < 0.02 | < 0.02 | < 0.02 | 1.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 1050.4 | 206.87 | 34.732 | 31.86 | 1.29 | 2.19 | < 0.02 | 0.02 | 102.50 |
17 | 1250.6 | < 0.02 | < 0.02 | < 0.02 | 1.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1250.7 | 209.15 | 34.722 | 32.28 | 1.07 | 2.22 | < 0.02 | 0.02 | 108.28 |
14 | 1500.1 | 211.69 | 34.707 | 32.83 | 0.84 | 2.25 | < 0.02 | 0.02 | 114.06 |
15 | 1500.1 | < 0.02 | < 0.02 | < 0.02 | 0.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1800.3 | 213.75 | 34.696 | 33.27 | 0.63 | 2.29 | < 0.02 | 0.02 | 120.57 |
13 | 1800.4 | < 0.02 | < 0.02 | < 0.02 | 0.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 2300 | 220.22 | 34.681 | 33.55 | 0.37 | 2.32 | < 0.02 | 0.02 | 127.20 |
10 | 2800.1 | 227.37 | 34.672 | 33.52 | 0.17 | 2.31 | < 0.02 | < 0.02 | 130.35 |
9 | 3300.7 | 233.35 | 34.666 | 33.47 | 0.03 | 2.31 | < 0.02 | < 0.02 | 133.12 |
8 | 3600.8 | 236.12 | 34.660 | 33.59 | -0.07 | 2.32 | < 0.02 | < 0.02 | 142.84 |
1 | 3632 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3634 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3664 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3664.1 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 3664.2 | 234.83 | 34.660 | 33.76 | -0.08 | 2.34 | 0.02 | < 0.02 | 151.73 |
6 | 3664.3 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3664.4 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |