Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 62
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-10 22:21 to 2021-03-11 01:01 UTC
Where: 64° 15.1' S 79° 59.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.1 | 338.08 | 33.716 | 22.60 | 0.62 | 1.52 | 1.21 | 0.28 | 9.14 |
36 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 0.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20.4 | 337.32 | 33.719 | 22.65 | 0.63 | 1.52 | 1.23 | 0.28 | 9.33 |
33 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 0.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 0.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 30.1 | 331.25 | 33.753 | 23.39 | 0.61 | 1.60 | 1.39 | 0.28 | 13.28 |
30 | 44.6 | 288.91 | < 0.02 | 29.38 | -0.01 | 2.14 | 1.73 | 0.24 | 46.47 |
29 | 44.7 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 54.8 | 273.59 | 34.176 | 32.26 | -0.72 | 2.32 | 1.07 | 0.24 | 62.56 |
27 | 70.1 | 245.05 | < 0.02 | 34.06 | -0.16 | 2.37 | 0.30 | 0.23 | 70.02 |
26 | 99.5 | 203.61 | 34.470 | 35.45 | 0.87 | 2.43 | < 0.02 | 0.04 | 79.99 |
25 | 149.8 | 184.05 | 34.562 | 35.63 | 1.46 | 2.45 | < 0.02 | 0.03 | 84.84 |
23 | 199.4 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 199.7 | 176.46 | 34.622 | 35.34 | 1.85 | 2.43 | < 0.02 | 0.02 | 87.59 |
21 | 251.2 | < 0.02 | < 0.02 | < 0.02 | 1.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 251.3 | 176.95 | 34.652 | 34.76 | 1.84 | 2.38 | < 0.02 | 0.02 | 88.66 |
20 | 301.6 | 180.43 | < 0.02 | 34.27 | 1.80 | 2.35 | < 0.02 | 0.02 | 89.59 |
19 | 500 | 189.14 | 34.719 | 32.72 | 1.81 | 2.25 | < 0.02 | < 0.02 | 90.90 |
18 | 500 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 850.9 | 201.33 | 34.726 | 31.98 | 1.47 | 2.20 | < 0.02 | < 0.02 | 97.16 |
17 | 851 | < 0.02 | < 0.02 | < 0.02 | 1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1099.9 | 207.14 | 34.734 | 31.77 | 1.31 | 2.19 | < 0.02 | < 0.02 | 100.70 |
15 | 1100 | < 0.02 | < 0.02 | < 0.02 | 1.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1501.3 | 210.58 | 34.713 | 32.60 | 0.92 | 2.26 | < 0.02 | < 0.02 | 111.76 |
12 | 1901.4 | 212.90 | 34.699 | 33.20 | 0.67 | 2.30 | < 0.02 | < 0.02 | 120.16 |
11 | 2299.2 | 218.04 | 34.685 | 33.52 | 0.44 | 2.32 | < 0.02 | < 0.02 | 125.05 |
10 | 2698.7 | 222.59 | 34.678 | 33.64 | 0.28 | 2.33 | < 0.02 | < 0.02 | 129.19 |
9 | 3097.9 | 228.04 | 34.671 | 33.30 | 0.17 | 2.32 | < 0.02 | < 0.02 | 130.40 |
8 | 3546.7 | 234.92 | 34.663 | 33.40 | -0.02 | 2.32 | < 0.02 | < 0.02 | 136.84 |
2 | 3661.1 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3661.3 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3687.8 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 3687.8 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3687.8 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 3687.8 | 236.03 | 34.659 | 33.44 | -0.07 | 2.33 | 0.02 | 0.02 | 140.78 |
4 | 3687.9 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |