Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 61
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-10 13:43 to 2021-03-10 16:29 UTC
Where: 63° 45.1' S 79° 59.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.4 | 338.04 | 33.695 | 22.70 | 0.72 | 1.48 | 1.42 | 0.30 | 11.80 |
36 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 0.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 24.9 | 331.47 | 33.744 | 23.22 | 0.77 | 1.56 | 1.71 | 0.30 | 15.33 |
34 | 24.9 | < 0.02 | < 0.02 | < 0.02 | 0.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 38.1 | 297.49 | 34.042 | 29.76 | -0.67 | 2.17 | 1.64 | 0.23 | 49.21 |
32 | 38.2 | < 0.02 | < 0.02 | < 0.02 | -0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 47 | 275.16 | 34.158 | 31.93 | -0.69 | 2.29 | 1.19 | 0.24 | 59.91 |
30 | 47.1 | < 0.02 | < 0.02 | < 0.02 | -0.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 70.2 | 225.27 | 34.363 | 34.84 | 0.31 | 2.41 | 0.07 | 0.19 | 73.44 |
27 | 89.1 | 196.42 | 34.478 | 35.64 | 1.09 | 2.45 | < 0.02 | 0.06 | 80.03 |
26 | 118.5 | 180.70 | 34.557 | 35.88 | 1.59 | 2.46 | < 0.02 | 0.05 | 84.39 |
24 | 175.3 | 173.42 | 34.629 | 35.41 | 1.90 | 2.42 | < 0.02 | 0.03 | 87.07 |
25 | 175.5 | < 0.02 | < 0.02 | < 0.02 | 1.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 275.8 | < 0.02 | < 0.02 | < 0.02 | 1.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 275.8 | 177.75 | 34.674 | 34.36 | 1.91 | 2.35 | < 0.02 | 0.03 | 88.72 |
21 | 374.7 | 182.89 | 34.699 | 33.55 | 1.88 | 2.29 | < 0.02 | 0.03 | 89.44 |
20 | 549.5 | 192.89 | 34.728 | 32.44 | 1.77 | 2.22 | < 0.02 | 0.02 | 90.61 |
18 | 698.6 | < 0.02 | < 0.02 | < 0.02 | 1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 698.6 | 198.70 | 34.735 | 32.00 | 1.62 | 2.19 | < 0.02 | 0.02 | 93.26 |
16 | 1000.8 | < 0.02 | < 0.02 | < 0.02 | 1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 1001 | 205.44 | 34.733 | 31.79 | 1.36 | 2.19 | < 0.02 | 0.02 | 99.19 |
15 | 1400.5 | 209.91 | 34.714 | 32.54 | 0.95 | 2.24 | < 0.02 | 0.02 | 110.90 |
13 | 1800.6 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1800.7 | 213.08 | 34.699 | 33.13 | 0.66 | 2.29 | < 0.02 | 0.02 | 120.06 |
12 | 2300.4 | 219.87 | 34.682 | 33.51 | 0.37 | 2.32 | < 0.02 | 0.02 | 126.75 |
10 | 2780 | 232.06 | 34.666 | 33.29 | 0.07 | 2.31 | < 0.02 | 0.02 | 125.01 |
11 | 2780.1 | < 0.02 | < 0.02 | < 0.02 | 0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 3200.2 | 233.67 | 34.666 | 33.26 | 0.05 | 2.30 | < 0.02 | 0.03 | 126.83 |
8 | 3700.9 | 236.88 | 34.661 | 33.28 | -0.02 | 2.31 | < 0.02 | 0.03 | 129.94 |
1 | 3701.1 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3705.5 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3730.2 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3730.3 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 3730.4 | 236.79 | 34.661 | 33.28 | -0.02 | 2.31 | < 0.02 | 0.03 | 131.43 |
7 | 3730.4 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3730.6 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |