Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 57
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-08 14:55 to 2021-03-08 16:42 UTC
Where: 63° 00.0' S 74° 59.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.8 | 336.92 | 33.701 | 22.98 | 0.81 | 1.54 | 1.47 | 0.30 | 11.47 |
36 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 0.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 0.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20.6 | 336.61 | 33.703 | 23.01 | 0.81 | 1.55 | 1.47 | 0.30 | 11.58 |
31 | 39.5 | < 0.02 | < 0.02 | < 0.02 | 0.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 39.8 | 336.12 | 33.711 | 23.20 | 0.78 | 1.58 | 1.51 | 0.30 | 12.48 |
30 | 50 | 319.55 | 33.886 | 27.16 | 0.55 | 1.92 | 1.51 | 0.26 | 32.87 |
29 | 50 | < 0.02 | < 0.02 | < 0.02 | 0.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 60.2 | 298.11 | 34.072 | 31.30 | -1.14 | 2.24 | 1.15 | 0.22 | 53.44 |
27 | 60.2 | < 0.02 | < 0.02 | < 0.02 | -1.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 100.8 | < 0.02 | < 0.02 | < 0.02 | 0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 100.8 | 220.49 | 34.352 | 35.46 | 0.67 | 2.42 | < 0.02 | 0.10 | 71.25 |
23 | 130.2 | < 0.02 | < 0.02 | < 0.02 | 1.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 130.2 | 193.07 | 34.465 | 36.28 | 1.42 | 2.47 | < 0.02 | 0.05 | 78.14 |
21 | 249.9 | < 0.02 | < 0.02 | < 0.02 | 1.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 249.9 | 173.02 | 34.607 | 35.81 | 1.93 | 2.44 | < 0.02 | 0.04 | 85.75 |
19 | 350.2 | < 0.02 | < 0.02 | < 0.02 | 1.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 350.2 | 176.01 | 34.667 | 34.58 | 1.99 | 2.36 | < 0.02 | 0.03 | 87.56 |
17 | 600.3 | 189.81 | 34.723 | 32.71 | 1.85 | 2.23 | < 0.02 | 0.03 | 90.19 |
18 | 600.4 | < 0.02 | < 0.02 | < 0.02 | 1.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 800.2 | 198.21 | 34.738 | 31.89 | 1.70 | 2.18 | < 0.02 | 0.03 | 92.01 |
14 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 1.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1000.8 | 203.12 | 34.739 | 31.68 | 1.54 | 2.15 | < 0.02 | 0.03 | 95.41 |
13 | 1200.3 | 206.56 | 34.733 | 31.88 | 1.32 | 2.18 | < 0.02 | 0.03 | 101.13 |
12 | 1400.7 | 208.61 | 34.725 | 32.23 | 1.14 | 2.19 | < 0.02 | 0.03 | 106.29 |
11 | 1600.8 | 210.67 | 34.715 | 32.62 | 0.96 | 2.22 | < 0.02 | 0.02 | 111.40 |
10 | 1801.1 | 211.69 | 34.708 | 32.93 | 0.83 | 2.25 | < 0.02 | 0.02 | 115.87 |
8 | 1998.9 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2000.3 | 212.72 | 34.703 | 33.29 | 0.69 | 2.28 | < 0.02 | 0.02 | 120.26 |
5 | 2249.8 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2250 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2250.1 | 214.91 | 34.694 | 33.53 | 0.57 | 2.30 | < 0.02 | 0.02 | 124.60 |
1 | 2250.3 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2250.4 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2250.6 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2250.9 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |