Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 55
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-07 14:00 to 2021-03-07 16:33 UTC
Where: 65° 00.0' S 75° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 6.5 | 346.17 | 33.643 | 20.82 | 0.38 | 1.32 | 0.14 | 0.28 | 3.98 |
35 | 7 | < 0.02 | < 0.02 | < 0.02 | 0.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15.5 | 345.72 | 33.644 | 20.70 | 0.38 | 1.32 | 0.14 | 0.28 | 3.93 |
33 | 27.9 | 342.51 | 33.672 | 21.32 | 0.36 | 1.39 | 0.25 | 0.27 | 6.83 |
31 | 37.6 | 310.04 | 33.989 | 27.69 | -0.80 | 2.01 | 1.15 | 0.23 | 43.17 |
32 | 37.9 | < 0.02 | < 0.02 | < 0.02 | -0.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 54.7 | 291.41 | 34.185 | 31.48 | -1.52 | 2.20 | 0.39 | 0.23 | 63.11 |
30 | 54.8 | < 0.02 | < 0.02 | < 0.02 | -1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 70.2 | 281.45 | 34.255 | 32.18 | -1.36 | 2.23 | 0.18 | 0.19 | 67.82 |
27 | 89.1 | 276.72 | 34.296 | 32.21 | -0.95 | 2.22 | < 0.02 | 0.05 | 67.47 |
26 | 121.7 | 248.49 | 34.405 | 32.99 | -0.33 | 2.27 | < 0.02 | 0.02 | 75.79 |
25 | 221.1 | 203.88 | 34.636 | 33.08 | 1.04 | 2.28 | < 0.02 | < 0.02 | 89.04 |
24 | 340.5 | 198.92 | 34.703 | 32.34 | 1.40 | 2.23 | < 0.02 | < 0.02 | 94.16 |
23 | 340.6 | < 0.02 | < 0.02 | < 0.02 | 1.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 500.5 | 211.11 | 34.695 | 32.00 | 1.06 | 2.21 | < 0.02 | < 0.02 | 95.74 |
20 | 650.1 | < 0.02 | < 0.02 | < 0.02 | 1.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 650.3 | 211.07 | 34.705 | 31.97 | 1.03 | 2.21 | < 0.02 | < 0.02 | 100.32 |
17 | 898.5 | 213.03 | 34.702 | 32.28 | 0.84 | 2.23 | < 0.02 | < 0.02 | 107.66 |
18 | 898.6 | < 0.02 | < 0.02 | < 0.02 | 0.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 898.6 | < 0.02 | < 0.02 | < 0.02 | 0.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1151.2 | 213.88 | 34.698 | 32.64 | 0.69 | 2.26 | < 0.02 | < 0.02 | 114.79 |
15 | 1501.1 | 216.29 | 34.689 | 33.09 | 0.48 | 2.30 | < 0.02 | < 0.02 | 122.49 |
14 | 1900.3 | 222.55 | 34.678 | 33.20 | 0.27 | 2.30 | < 0.02 | < 0.02 | 127.03 |
13 | 1900.3 | < 0.02 | < 0.02 | < 0.02 | 0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 2300.2 | < 0.02 | < 0.02 | < 0.02 | 0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 2300.3 | 227.91 | 34.672 | 33.18 | 0.12 | 2.30 | < 0.02 | < 0.02 | 128.81 |
9 | 2800.4 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 2800.4 | 233.44 | 34.666 | 33.04 | 0.01 | 2.29 | < 0.02 | < 0.02 | 128.54 |
8 | 3200.4 | 237.33 | 34.660 | 33.04 | -0.07 | 2.29 | < 0.02 | < 0.02 | 130.67 |
1 | 3243.2 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3245.7 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3276.5 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3276.9 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 3276.9 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 3276.9 | 235.90 | 34.659 | 33.31 | -0.11 | 2.32 | < 0.02 | < 0.02 | 144.38 |
5 | 3277.1 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |