Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 53
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-06 15:19 to 2021-03-06 17:25 UTC
Where: 66° 30.0' S 75° 00.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.2 | < 0.02 | < 0.02 | < 0.02 | -0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.2 | 351.57 | 33.591 | 22.60 | -0.44 | 1.41 | 0.09 | 0.21 | 12.04 |
34 | 25.6 | 350.59 | 33.597 | 22.74 | -0.44 | 1.43 | 0.12 | 0.21 | 12.57 |
33 | 25.7 | < 0.02 | < 0.02 | < 0.02 | -0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 35.2 | < 0.02 | < 0.02 | 22.95 | -0.49 | 1.46 | 0.18 | 0.21 | 13.68 |
31 | 35.2 | < 0.02 | < 0.02 | < 0.02 | -0.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.4 | < 0.02 | < 0.02 | 24.66 | -0.52 | 1.66 | 0.45 | 0.20 | 22.76 |
29 | 50.3 | 310.30 | < 0.02 | 30.13 | -1.57 | 2.11 | 0.67 | 0.17 | 53.99 |
28 | 60.4 | 307.67 | 34.126 | 30.52 | -1.65 | 2.13 | 0.49 | 0.22 | 55.58 |
27 | 75.2 | 305.88 | 34.150 | 30.81 | -1.67 | 2.13 | 0.28 | 0.29 | 56.11 |
25 | 150.1 | < 0.02 | < 0.02 | < 0.02 | -1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 150.2 | 308.12 | 34.277 | 30.79 | -1.55 | 2.11 | < 0.02 | 0.03 | 58.19 |
23 | 250 | < 0.02 | < 0.02 | < 0.02 | -0.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 250.1 | 266.72 | 34.443 | 32.60 | -0.53 | 2.23 | < 0.02 | 0.02 | 73.23 |
22 | 350.6 | 246.84 | 34.552 | 32.84 | 0.07 | 2.25 | < 0.02 | 0.02 | 81.46 |
21 | 350.6 | < 0.02 | < 0.02 | < 0.02 | 0.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 499.8 | < 0.02 | < 0.02 | < 0.02 | 0.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 499.9 | 241.26 | 34.612 | 32.50 | 0.21 | 2.23 | < 0.02 | 0.02 | 88.46 |
16 | 701 | 222.68 | 34.673 | 32.70 | 0.59 | 2.24 | < 0.02 | 0.11 | 102.33 |
17 | 701.1 | < 0.02 | < 0.02 | < 0.02 | 0.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 701.1 | < 0.02 | < 0.02 | < 0.02 | 0.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 850.6 | 220.49 | 34.682 | 32.92 | 0.56 | 2.26 | < 0.02 | 0.11 | 109.00 |
14 | 850.7 | < 0.02 | < 0.02 | < 0.02 | 0.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 0.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1000.7 | 221.61 | 34.679 | 33.14 | 0.45 | 2.28 | < 0.02 | 0.02 | 114.01 |
11 | 1300.5 | 223.26 | 34.678 | 33.41 | 0.31 | 2.30 | < 0.02 | 0.02 | 121.33 |
10 | 1700.3 | 227.73 | 34.674 | 33.41 | 0.16 | 2.30 | < 0.02 | 0.02 | 124.94 |
9 | 2000.3 | 230.58 | 34.670 | 33.38 | 0.07 | 2.30 | < 0.02 | 0.02 | 126.86 |
8 | 2400.3 | 234.29 | 34.674 | 33.40 | -0.05 | 2.31 | < 0.02 | 0.02 | 129.96 |
2 | 2442 | < 0.02 | < 0.02 | < 0.02 | -0.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2442.1 | < 0.02 | < 0.02 | < 0.02 | -0.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2469 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2469 | 234.65 | 34.662 | 33.47 | -0.10 | 2.32 | < 0.02 | 0.02 | 134.72 |
7 | 2469 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2469 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2469.1 | < 0.02 | < 0.02 | < 0.02 | -0.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |