Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 52
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-06 11:31 to 2021-03-06 13:36 UTC
Where: 66° 39.0' S 75° 00.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.2 | 352.29 | 33.570 | 22.63 | -0.43 | 1.42 | 0.07 | 0.21 | 11.95 |
36 | 5.2 | < 0.02 | < 0.02 | < 0.02 | -0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 25.2 | 347.33 | 33.622 | 23.31 | -0.47 | 1.48 | 0.16 | 0.20 | 15.76 |
34 | 25.2 | < 0.02 | < 0.02 | < 0.02 | -0.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 35.7 | < 0.02 | < 0.02 | < 0.02 | -1.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 35.7 | 312.81 | 34.081 | 29.68 | -1.57 | 2.10 | 0.79 | 0.25 | 52.51 |
30 | 50.8 | 309.37 | 34.143 | 30.35 | -1.65 | 2.11 | 0.48 | 0.18 | 54.97 |
29 | 60.1 | 308.88 | 34.166 | 30.57 | -1.67 | 2.12 | 0.31 | 0.20 | 55.31 |
28 | 90.4 | 309.72 | 34.235 | 30.75 | -1.65 | 2.10 | < 0.02 | 0.11 | 56.20 |
26 | 130.3 | 316.69 | 34.262 | 30.41 | -1.72 | 2.07 | < 0.02 | 0.04 | 55.55 |
27 | 130.4 | < 0.02 | < 0.02 | < 0.02 | -1.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 200.3 | 314.68 | 34.295 | 30.51 | -1.62 | 2.08 | < 0.02 | 0.02 | 57.33 |
24 | 300.9 | 284.04 | 34.413 | 32.05 | -0.88 | 2.18 | < 0.02 | < 0.02 | 68.49 |
22 | 450.8 | 267.74 | 34.527 | 32.37 | -0.49 | 2.21 | < 0.02 | < 0.02 | 78.51 |
23 | 450.8 | < 0.02 | < 0.02 | < 0.02 | -0.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 650.7 | 224.87 | 34.662 | 32.58 | 0.55 | 2.22 | < 0.02 | 0.02 | 98.26 |
18 | 801 | < 0.02 | < 0.02 | < 0.02 | 0.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 801.1 | 222.05 | 34.673 | 32.73 | 0.53 | 2.23 | < 0.02 | 0.02 | 105.44 |
19 | 801.1 | < 0.02 | < 0.02 | < 0.02 | 0.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1100.3 | < 0.02 | < 0.02 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1100.3 | 220.63 | 34.682 | 33.06 | 0.43 | 2.27 | < 0.02 | 0.02 | 116.71 |
17 | 1100.3 | < 0.02 | < 0.02 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1400.7 | 223.31 | 34.678 | 33.25 | 0.28 | 2.34 | < 0.02 | 0.02 | 122.36 |
13 | 1400.7 | < 0.02 | < 0.02 | < 0.02 | 0.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 1750.3 | < 0.02 | < 0.02 | < 0.02 | 0.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1750.4 | 227.59 | 34.673 | 33.29 | 0.14 | 2.34 | < 0.02 | 0.02 | 125.28 |
10 | 2100.6 | 231.79 | 34.668 | 33.32 | 0.01 | 2.34 | < 0.02 | 0.02 | 128.31 |
9 | 2100.6 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 2100.6 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2153.2 | < 0.02 | < 0.02 | < 0.02 | -0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2155.3 | < 0.02 | < 0.02 | < 0.02 | -0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2180.2 | 232.10 | 34.667 | 33.36 | -0.02 | 2.34 | < 0.02 | 0.02 | 130.67 |
4 | 2180.2 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2180.2 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2180.2 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2180.3 | < 0.02 | < 0.02 | < 0.02 | -0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |