Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 49
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-05 14:24 to 2021-03-05 15:12 UTC
Where: 67° 19.9' S 74° 35.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | -1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.1 | < 0.02 | < 0.02 | < 0.02 | -1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.1 | 351.17 | 33.537 | 25.51 | -1.00 | 1.74 | 1.02 | 0.16 | 34.85 |
32 | 19.9 | < 0.02 | < 0.02 | < 0.02 | -1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20 | < 0.02 | < 0.02 | < 0.02 | -1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 20 | 348.67 | 33.583 | 25.81 | -1.01 | 1.77 | 1.00 | 0.15 | 36.63 |
30 | 40 | < 0.02 | < 0.02 | < 0.02 | -1.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 40 | < 0.02 | < 0.02 | < 0.02 | -1.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 40 | 324.86 | 34.097 | 29.49 | -1.57 | 2.04 | 0.43 | 0.14 | 55.20 |
25 | 65.2 | 315.13 | 34.288 | 30.94 | -1.68 | 2.14 | 0.18 | 0.26 | 59.61 |
26 | 65.3 | < 0.02 | < 0.02 | < 0.02 | -1.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 65.3 | < 0.02 | < 0.02 | < 0.02 | -1.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 100.6 | 312.89 | 34.364 | 31.36 | -1.61 | 2.15 | < 0.02 | 0.05 | 62.69 |
23 | 100.7 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 100.7 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 151.1 | < 0.02 | < 0.02 | < 0.02 | -1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 151.1 | 310.44 | 34.422 | 31.51 | -1.53 | 2.17 | < 0.02 | 0.02 | 65.90 |
21 | 151.1 | < 0.02 | < 0.02 | < 0.02 | -1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 250.8 | 326.16 | 34.459 | 31.09 | -1.83 | 2.14 | < 0.02 | 0.02 | 63.92 |
17 | 250.9 | < 0.02 | < 0.02 | < 0.02 | -1.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 251 | < 0.02 | < 0.02 | < 0.02 | -1.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 350.6 | 321.07 | 34.493 | 31.36 | -1.80 | 2.16 | < 0.02 | 0.03 | 66.57 |
14 | 350.7 | < 0.02 | < 0.02 | < 0.02 | -1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 350.8 | < 0.02 | < 0.02 | < 0.02 | -1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 400.5 | < 0.02 | < 0.02 | < 0.02 | -1.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 400.5 | 322.77 | 34.518 | 31.49 | -1.90 | 2.18 | < 0.02 | 0.04 | 68.82 |
12 | 400.5 | < 0.02 | < 0.02 | < 0.02 | -1.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 418.3 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 421.6 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 425.3 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 425.3 | 313.43 | 34.534 | 31.88 | -1.87 | 2.24 | < 0.02 | 0.06 | 78.03 |
7 | 449.1 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 449.1 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 449.1 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 449.2 | < 0.02 | < 0.02 | < 0.02 | -1.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 449.2 | 312.98 | 34.534 | 31.94 | -1.87 | 2.25 | < 0.02 | 0.06 | 78.64 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |