Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 45
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-03 09:16 to 2021-03-03 11:35 UTC
Where: 65° 55.0' S 69° 59.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 12.4 | 344.38 | 33.827 | 28.31 | -0.75 | 1.87 | 0.11 | 0.21 | 52.42 |
36 | 12.5 | < 0.02 | < 0.02 | < 0.02 | -0.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 25 | 343.98 | 33.828 | 28.33 | -0.75 | 1.88 | 0.11 | 0.20 | 52.41 |
32 | 45.5 | 338.04 | 33.875 | 28.67 | -0.76 | 1.91 | 0.12 | 0.20 | 54.27 |
33 | 45.6 | < 0.02 | < 0.02 | < 0.02 | -0.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 60.3 | < 0.02 | < 0.02 | < 0.02 | -1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 60.3 | 293.82 | 34.308 | 31.69 | -1.55 | 2.19 | 0.18 | 0.18 | 71.62 |
29 | 80.7 | 276.14 | 34.368 | 32.40 | -1.16 | 2.22 | 0.02 | 0.18 | 75.05 |
28 | 80.7 | < 0.02 | < 0.02 | < 0.02 | -1.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 125.6 | 233.89 | 34.557 | 32.85 | 0.20 | 2.26 | < 0.02 | 0.02 | 86.84 |
26 | 200.2 | 219.78 | 34.643 | 32.70 | 0.69 | 2.25 | < 0.02 | < 0.02 | 92.27 |
24 | 300.3 | < 0.02 | < 0.02 | < 0.02 | 0.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 300.4 | 215.00 | 34.682 | 32.51 | 0.87 | 2.24 | < 0.02 | < 0.02 | 97.14 |
22 | 450.5 | < 0.02 | < 0.02 | < 0.02 | 0.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 450.6 | 217.37 | 34.686 | 32.48 | 0.74 | 2.24 | < 0.02 | < 0.02 | 102.15 |
21 | 700.1 | 219.15 | 34.684 | 32.79 | 0.56 | 2.27 | < 0.02 | < 0.02 | 110.39 |
18 | 950.3 | < 0.02 | < 0.02 | < 0.02 | 0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 950.4 | 220.04 | 34.682 | 33.04 | 0.44 | 2.29 | < 0.02 | < 0.02 | 116.65 |
19 | 950.4 | < 0.02 | < 0.02 | < 0.02 | 0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 1250.6 | < 0.02 | < 0.02 | < 0.02 | 0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1250.6 | 223.57 | 34.677 | 33.20 | 0.27 | 2.31 | < 0.02 | < 0.02 | 122.04 |
16 | 1250.7 | < 0.02 | < 0.02 | < 0.02 | 0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1650.2 | 228.26 | 34.671 | 33.18 | 0.12 | 2.31 | < 0.02 | < 0.02 | 125.39 |
14 | 1650.3 | < 0.02 | < 0.02 | < 0.02 | 0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 2000.4 | < 0.02 | < 0.02 | < 0.02 | 0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 2000.4 | 232.19 | 34.666 | 33.16 | 0.02 | 2.31 | < 0.02 | < 0.02 | 126.54 |
10 | 2480.5 | < 0.02 | < 0.02 | < 0.02 | -0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2480.6 | 241.97 | 34.649 | 33.24 | -0.27 | 2.33 | < 0.02 | 0.02 | 136.15 |
8 | 2480.6 | < 0.02 | < 0.02 | < 0.02 | -0.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2499.6 | < 0.02 | < 0.02 | < 0.02 | -0.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2502.1 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2528.9 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2529 | 248.45 | 34.638 | 33.10 | -0.35 | 2.32 | < 0.02 | 0.02 | 128.12 |
4 | 2529 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2529 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2529.2 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |