Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 42
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-02 12:46 to 2021-03-02 15:23 UTC
Where: 65° 01.0' S 70° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.8 | 345.50 | 33.668 | 27.75 | -0.37 | 1.82 | 0.12 | 0.25 | 51.62 |
36 | 5.8 | < 0.02 | < 0.02 | < 0.02 | -0.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15.3 | 345.68 | 33.668 | 27.72 | -0.37 | 1.83 | 0.12 | 0.24 | 51.67 |
33 | 15.4 | < 0.02 | < 0.02 | < 0.02 | -0.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 35.4 | < 0.02 | < 0.02 | < 0.02 | -0.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 35.5 | 342.68 | 33.712 | 27.90 | -0.37 | 1.83 | 0.12 | 0.23 | 52.53 |
30 | 45.4 | 318.88 | 34.090 | 29.78 | -1.19 | 2.00 | 0.06 | 0.15 | 61.66 |
29 | 65.6 | 296.46 | 34.282 | 31.50 | -1.48 | 2.15 | 0.11 | 0.15 | 69.28 |
28 | 65.6 | < 0.02 | < 0.02 | < 0.02 | -1.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 80.7 | 288.29 | 34.314 | 32.07 | -1.47 | 2.19 | 0.10 | 0.18 | 71.70 |
26 | 110.6 | 268.64 | 34.388 | 32.54 | -0.92 | 2.22 | < 0.02 | 0.08 | 75.78 |
24 | 150.3 | < 0.02 | < 0.02 | < 0.02 | 0.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 150.3 | 235.23 | 34.543 | 32.90 | 0.13 | 2.24 | < 0.02 | 0.02 | 84.92 |
22 | 250.1 | < 0.02 | < 0.02 | < 0.02 | 1.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 250.2 | 206.74 | 34.682 | 32.64 | 1.12 | 2.24 | < 0.02 | < 0.02 | 93.66 |
21 | 350.7 | 207.41 | 34.704 | 32.41 | 1.15 | 2.22 | < 0.02 | < 0.02 | 97.53 |
20 | 350.7 | < 0.02 | < 0.02 | < 0.02 | 1.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 0.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 500.6 | 211.38 | 34.702 | 32.54 | 0.97 | 2.22 | 0.07 | 0.02 | 101.38 |
16 | 800.9 | 216.16 | 34.691 | 32.88 | 0.69 | 2.25 | < 0.02 | 0.02 | 108.57 |
17 | 800.9 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1101 | 215.98 | 34.689 | 33.18 | 0.54 | 2.28 | < 0.02 | < 0.02 | 117.24 |
13 | 1500.9 | < 0.02 | < 0.02 | < 0.02 | 0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1500.9 | 220.89 | 34.680 | 33.50 | 0.31 | 2.31 | < 0.02 | < 0.02 | 124.43 |
11 | 2000.5 | 228.98 | 34.669 | 33.43 | 0.09 | 2.30 | < 0.02 | < 0.02 | 126.36 |
12 | 2000.5 | < 0.02 | < 0.02 | < 0.02 | 0.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2500.6 | < 0.02 | < 0.02 | < 0.02 | -0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 2500.7 | 233.67 | 34.665 | 33.38 | -0.01 | 2.29 | < 0.02 | < 0.02 | 127.37 |
8 | 2890.7 | 238.76 | 34.658 | 33.51 | -0.16 | 2.31 | < 0.02 | < 0.02 | 136.01 |
1 | 2898.9 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2900.4 | < 0.02 | < 0.02 | < 0.02 | -0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2928.9 | < 0.02 | < 0.02 | < 0.02 | -0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2929.1 | < 0.02 | < 0.02 | < 0.02 | -0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2929.1 | < 0.02 | < 0.02 | < 0.02 | -0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2929.1 | 238.22 | 34.655 | 33.72 | -0.18 | 2.32 | < 0.02 | < 0.02 | 142.17 |
4 | 2929.2 | < 0.02 | < 0.02 | < 0.02 | -0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |