Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 37
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-03-01 05:00 to 2021-03-01 08:04 UTC
Where: 63° 58.0' S 69° 59.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 10.2 | 350.99 | 33.422 | 25.18 | -0.05 | 1.63 | 0.11 | 0.24 | 42.79 |
36 | 10.3 | < 0.02 | < 0.02 | < 0.02 | -0.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 25.2 | 351.08 | 33.422 | 25.16 | -0.06 | 1.64 | 0.11 | 0.26 | 42.96 |
34 | 25.3 | < 0.02 | < 0.02 | < 0.02 | -0.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 35.5 | < 0.02 | < 0.02 | < 0.02 | -0.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 35.5 | 348.85 | 33.463 | 25.40 | -0.05 | 1.66 | 0.12 | 0.23 | 43.68 |
30 | 45.5 | 322.14 | 34.020 | 29.40 | -1.23 | 2.01 | 0.14 | 0.16 | 57.20 |
28 | 60.4 | 304.32 | 34.208 | 30.95 | -1.51 | 2.13 | 0.17 | 0.13 | 63.56 |
29 | 60.5 | < 0.02 | < 0.02 | < 0.02 | -1.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 90.5 | 290.39 | 34.314 | 32.12 | -1.51 | 2.20 | 0.03 | 0.17 | 68.26 |
26 | 120.6 | 266.00 | 34.421 | 32.84 | -0.62 | 2.25 | 0.02 | 0.07 | 72.92 |
25 | 180.5 | 240.41 | 34.528 | 33.10 | 0.05 | 2.27 | 0.03 | 0.04 | 79.57 |
23 | 241 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 241 | 207.54 | 34.634 | 33.40 | 1.02 | 2.29 | < 0.02 | 0.03 | 88.42 |
22 | 300.9 | 211.92 | 34.641 | 33.05 | 0.93 | 2.27 | < 0.02 | 0.02 | 89.26 |
20 | 381.3 | < 0.02 | < 0.02 | < 0.02 | 1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 381.4 | 196.69 | 34.713 | 32.60 | 1.47 | 2.24 | < 0.02 | 0.02 | 95.15 |
19 | 550.4 | 204.28 | 34.711 | 32.28 | 1.25 | 2.22 | < 0.02 | 0.02 | 97.74 |
18 | 550.5 | < 0.02 | < 0.02 | < 0.02 | 1.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 741.2 | 206.91 | 34.719 | 32.20 | 1.13 | 2.22 | < 0.02 | 0.02 | 103.08 |
17 | 741.4 | < 0.02 | < 0.02 | < 0.02 | 1.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1050.8 | 209.59 | 34.711 | 32.60 | 0.89 | 2.26 | < 0.02 | 0.02 | 111.72 |
15 | 1051 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1401.5 | 212.18 | 34.701 | 33.14 | 0.66 | 2.29 | < 0.02 | 0.02 | 118.67 |
12 | 1800.7 | 217.28 | 34.686 | 33.46 | 0.43 | 2.31 | < 0.02 | 0.02 | 124.20 |
11 | 2251.1 | 223.31 | 34.676 | 33.54 | 0.23 | 2.32 | < 0.02 | 0.02 | 129.53 |
10 | 2700.6 | 231.84 | 34.667 | 33.39 | 0.06 | 2.31 | < 0.02 | 0.02 | 127.39 |
9 | 3151.1 | 234.65 | 34.666 | 33.29 | 0.00 | 2.30 | < 0.02 | 0.02 | 128.14 |
8 | 3151.1 | < 0.02 | < 0.02 | < 0.02 | 0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3553 | < 0.02 | < 0.02 | < 0.02 | -0.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3555.2 | < 0.02 | < 0.02 | < 0.02 | -0.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3585.4 | < 0.02 | < 0.02 | < 0.02 | -0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 3585.5 | < 0.02 | < 0.02 | < 0.02 | -0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3585.5 | < 0.02 | < 0.02 | < 0.02 | -0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3585.6 | < 0.02 | < 0.02 | < 0.02 | -0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 3585.6 | 234.92 | 34.660 | 34.00 | -0.12 | 2.36 | < 0.02 | 0.02 | 157.51 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |