Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 34
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-28 06:08 to 2021-02-28 09:44 UTC
Where: 62° 50.0' S 70° 00.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 15.7 | 340.99 | 33.654 | 23.29 | 0.91 | 1.46 | 0.67 | 0.30 | 12.12 |
36 | 15.8 | < 0.02 | < 0.02 | < 0.02 | 0.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 24.6 | 340.90 | 33.665 | 23.38 | 0.89 | 1.46 | 0.67 | 0.30 | 11.79 |
32 | 53.2 | 340.23 | 33.722 | 24.06 | 0.67 | 1.54 | 0.91 | 0.30 | 13.39 |
33 | 53.2 | < 0.02 | < 0.02 | < 0.02 | 0.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 65.5 | 312.54 | 34.012 | 30.45 | -1.25 | 2.17 | 0.95 | 0.21 | 50.08 |
30 | 80.4 | 294.99 | 34.082 | 31.67 | -0.88 | 2.22 | 0.52 | 0.20 | 54.46 |
29 | 90.6 | 262.38 | 34.198 | 33.74 | -0.09 | 2.31 | 0.04 | 0.16 | 61.25 |
28 | 120.7 | 199.28 | 34.434 | 36.19 | 1.44 | 2.48 | < 0.02 | 0.04 | 75.98 |
27 | 200.6 | 174.85 | 34.568 | 36.15 | 1.93 | 2.47 | < 0.02 | 0.02 | 83.33 |
25 | 270.9 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 270.9 | 172.88 | 34.619 | 35.51 | 2.01 | 2.43 | < 0.02 | 0.02 | 85.89 |
24 | 310.7 | 173.95 | 34.642 | 34.95 | 2.02 | 2.39 | < 0.02 | < 0.02 | 86.22 |
22 | 360.6 | < 0.02 | < 0.02 | < 0.02 | 2.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 360.8 | 175.83 | 34.662 | 34.49 | 2.03 | 2.36 | < 0.02 | 0.02 | 86.65 |
21 | 660.4 | 189.27 | 34.722 | 32.62 | 1.87 | 2.23 | < 0.02 | 0.02 | 90.58 |
19 | 960.3 | < 0.02 | < 0.02 | < 0.02 | 1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 960.4 | < 0.02 | < 0.02 | < 0.02 | 1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 960.4 | 201.96 | 34.743 | 31.48 | 1.62 | 2.16 | < 0.02 | 0.02 | 94.10 |
17 | 1300.6 | 208.21 | 34.734 | 31.75 | 1.28 | 2.18 | < 0.02 | 0.02 | 102.94 |
15 | 1500.9 | < 0.02 | < 0.02 | < 0.02 | 1.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1501 | 209.68 | 34.723 | 32.21 | 1.08 | 2.22 | < 0.02 | 0.02 | 108.71 |
14 | 1700.4 | 210.93 | 34.713 | 32.58 | 0.91 | 2.24 | < 0.02 | 0.02 | 113.98 |
13 | 2000.7 | 212.05 | 34.699 | 33.27 | 0.67 | 2.29 | < 0.02 | < 0.02 | 121.50 |
12 | 2000.8 | < 0.02 | < 0.02 | < 0.02 | 0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 2501.2 | 217.01 | 34.687 | 33.68 | 0.43 | 2.32 | < 0.02 | < 0.02 | 129.71 |
10 | 3000.5 | 224.56 | 34.676 | 33.76 | 0.21 | 2.33 | < 0.02 | < 0.02 | 135.21 |
9 | 3400.6 | 231.17 | 34.668 | 33.79 | 0.05 | 2.33 | < 0.02 | < 0.02 | 137.55 |
8 | 3901 | 238.85 | 34.660 | 33.71 | -0.12 | 2.33 | < 0.02 | < 0.02 | 144.63 |
1 | 4053.3 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 4056.1 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 4080.8 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 4081.1 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 4081.4 | 240.77 | 34.655 | 33.64 | -0.17 | 2.33 | < 0.02 | 0.02 | 153.20 |
7 | 4081.5 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 4081.7 | < 0.02 | < 0.02 | < 0.02 | -0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |