Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 32
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-27 18:01 to 2021-02-27 19:50 UTC
Where: 62° 00.0' S 70° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 10.7 | 338.80 | 33.693 | 22.75 | 1.12 | 1.46 | 0.98 | 0.30 | 9.11 |
35 | 10.9 | < 0.02 | < 0.02 | < 0.02 | 1.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 1.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 25.3 | 338.44 | 33.693 | 22.73 | 1.12 | 1.45 | 1.02 | 0.30 | 9.14 |
31 | 39.9 | < 0.02 | < 0.02 | < 0.02 | 1.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 40.4 | 338.40 | 33.693 | 22.70 | 1.12 | 1.46 | 0.98 | 0.31 | 9.15 |
30 | 51 | 336.57 | 33.714 | 23.13 | 1.06 | 1.53 | 1.21 | 0.30 | 11.81 |
29 | 51 | < 0.02 | < 0.02 | < 0.02 | 1.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 60.4 | < 0.02 | < 0.02 | < 0.02 | -1.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 60.5 | 315.49 | 33.983 | 29.25 | -1.10 | 2.17 | 1.63 | 0.22 | 48.11 |
25 | 89.7 | < 0.02 | < 0.02 | < 0.02 | -0.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 89.8 | 274.93 | 34.176 | 32.77 | -0.78 | 2.27 | 0.29 | 0.24 | 61.63 |
24 | 150.7 | 200.97 | 34.459 | 35.68 | 1.12 | 2.44 | < 0.02 | 0.05 | 79.45 |
23 | 200.3 | 177.21 | 34.576 | 35.98 | 1.76 | 2.46 | < 0.02 | 0.04 | 86.42 |
22 | 250.5 | 174.40 | 34.616 | 35.56 | 1.86 | 2.43 | < 0.02 | 0.04 | 88.59 |
21 | 250.6 | < 0.02 | < 0.02 | < 0.02 | 1.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 300.8 | 175.43 | 34.654 | 34.98 | 1.96 | 2.38 | < 0.02 | 0.03 | 88.82 |
19 | 300.9 | < 0.02 | < 0.02 | < 0.02 | 1.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 450.1 | 182.31 | 34.692 | 33.77 | 1.89 | 2.30 | < 0.02 | 0.02 | 90.94 |
17 | 600.6 | < 0.02 | 34.718 | 33.03 | 1.79 | 2.24 | < 0.02 | < 0.02 | 92.23 |
16 | 799.9 | < 0.02 | 34.733 | 32.13 | 1.68 | 2.19 | < 0.02 | 0.02 | 93.67 |
14 | 996.9 | 202.45 | 34.738 | 31.90 | 1.50 | 2.17 | < 0.02 | < 0.02 | 97.27 |
15 | 997.1 | < 0.02 | < 0.02 | < 0.02 | 1.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1197.9 | 206.29 | 34.734 | 31.92 | 1.33 | 2.17 | < 0.02 | < 0.02 | 101.40 |
12 | 1398.8 | 208.52 | 34.726 | 32.17 | 1.15 | 2.19 | < 0.02 | < 0.02 | 106.67 |
11 | 1599.5 | 210.35 | 34.717 | 32.52 | 0.98 | 2.22 | < 0.02 | < 0.02 | 111.97 |
10 | 1800.3 | 212.18 | 34.707 | 32.85 | 0.84 | 2.24 | < 0.02 | < 0.02 | 116.18 |
8 | 2001 | 212.68 | 34.702 | 33.21 | 0.71 | 2.27 | < 0.02 | < 0.02 | 120.58 |
9 | 2001.1 | < 0.02 | < 0.02 | < 0.02 | 0.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2248.8 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2249.2 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2249.2 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2249.2 | 214.19 | 34.695 | 33.42 | 0.58 | 2.29 | < 0.02 | < 0.02 | 125.11 |
3 | 2249.2 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2249.2 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2249.4 | < 0.02 | < 0.02 | < 0.02 | 0.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |