Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 30
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-26 10:15 to 2021-02-26 11:43 UTC
Where: 63° 00.1' S 65° 00.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.2 | 354.34 | 33.547 | 22.59 | 0.95 | 1.35 | 0.02 | 0.32 | 17.13 |
36 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 0.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20.4 | 354.03 | 33.550 | 22.65 | 0.93 | 1.36 | 0.03 | 0.32 | 17.04 |
34 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 0.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 40.3 | 357.60 | 33.660 | 23.81 | 0.01 | 1.54 | 0.09 | 0.30 | 20.79 |
32 | 40.3 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 50.5 | < 0.02 | < 0.02 | < 0.02 | -1.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 50.6 | 343.62 | 33.937 | 28.26 | -1.55 | 2.02 | 0.49 | 0.23 | 41.46 |
28 | 60.5 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 60.5 | 328.93 | 34.008 | 29.37 | -1.61 | 2.09 | 0.71 | 0.25 | 47.83 |
26 | 70.7 | < 0.02 | < 0.02 | < 0.02 | -1.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 70.7 | 320.53 | 34.058 | 30.06 | -1.48 | 2.12 | 0.57 | 0.27 | 50.64 |
24 | 100.5 | 266.89 | 34.239 | 33.11 | -0.26 | 2.29 | < 0.02 | 0.09 | 63.40 |
23 | 150.5 | 196.82 | 34.492 | 35.61 | 1.30 | 2.45 | < 0.02 | 0.03 | 80.59 |
22 | 225.5 | 178.51 | 34.591 | 35.58 | 1.77 | 2.45 | < 0.02 | 0.03 | 86.47 |
20 | 300.1 | < 0.02 | < 0.02 | < 0.02 | 1.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 300.2 | 175.79 | 34.644 | 34.93 | 1.90 | 2.40 | < 0.02 | 0.02 | 88.23 |
17 | 450.4 | 182.17 | 34.695 | 33.57 | 1.89 | 2.30 | < 0.02 | 0.02 | 89.62 |
19 | 450.5 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 450.5 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 600.6 | 190.84 | 34.727 | 32.36 | 1.87 | 2.22 | < 0.02 | 0.02 | 89.14 |
15 | 800.8 | 197.80 | 34.735 | 31.94 | 1.66 | 2.19 | < 0.02 | 0.02 | 93.40 |
14 | 800.8 | < 0.02 | < 0.02 | < 0.02 | 1.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1101.3 | 204.64 | 34.735 | 31.77 | 1.38 | 2.19 | < 0.02 | 0.02 | 99.38 |
11 | 1101.3 | < 0.02 | < 0.02 | < 0.02 | 1.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1101.5 | < 0.02 | < 0.02 | < 0.02 | 1.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 1300.4 | 206.96 | 34.725 | 32.17 | 1.16 | 2.22 | < 0.02 | 0.02 | 105.20 |
9 | 1300.4 | < 0.02 | < 0.02 | < 0.02 | 1.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1499.4 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1499.7 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1499.8 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 1499.8 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1499.8 | 209.77 | 34.721 | 32.31 | 1.01 | 2.23 | < 0.02 | 0.02 | 109.37 |
6 | 1499.9 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1499.9 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1500.1 | < 0.02 | < 0.02 | < 0.02 | 1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |