Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 28
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-25 11:34 to 2021-02-25 15:01 UTC
Where: 64° 30.0' S 65° 00.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.1 | 351.17 | 33.476 | 25.32 | 0.12 | 1.70 | 0.57 | 0.26 | 41.22 |
36 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15.3 | 350.77 | 33.482 | 25.43 | 0.01 | 1.71 | 0.57 | 0.25 | 41.40 |
33 | 30.8 | 337.68 | 33.994 | 28.62 | -1.36 | 2.02 | 0.64 | 0.21 | 47.74 |
32 | 40.6 | 327.37 | 34.054 | 29.57 | -1.43 | 2.06 | 0.50 | 0.22 | 50.83 |
31 | 40.6 | < 0.02 | < 0.02 | < 0.02 | -1.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 60.1 | 293.65 | 34.186 | 31.60 | -0.91 | 2.19 | 0.25 | 0.21 | 59.52 |
29 | 75.5 | 258.27 | 34.291 | 33.47 | -0.17 | 2.31 | 0.13 | 0.17 | 67.49 |
28 | 90.6 | 221.34 | 34.408 | 35.01 | 0.68 | 2.39 | < 0.02 | 0.13 | 76.15 |
27 | 120.7 | 195.35 | 34.511 | 35.68 | 1.34 | 2.44 | < 0.02 | 0.05 | 82.89 |
26 | 149.9 | 182.48 | 34.578 | 35.72 | 1.66 | 2.44 | < 0.02 | 0.03 | 87.15 |
24 | 200.7 | < 0.02 | < 0.02 | < 0.02 | 1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 200.7 | 177.93 | 34.631 | 35.18 | 1.80 | 2.40 | < 0.02 | 0.03 | 89.45 |
23 | 300.5 | 181.59 | 34.684 | 34.03 | 1.81 | 2.32 | < 0.02 | 0.02 | 91.48 |
22 | 450.5 | 188.87 | 34.713 | 33.00 | 1.68 | 2.25 | < 0.02 | < 0.02 | 94.18 |
21 | 600.4 | 195.66 | 34.724 | 32.55 | 1.55 | 2.22 | < 0.02 | < 0.02 | 96.84 |
18 | 800.5 | < 0.02 | < 0.02 | < 0.02 | 1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 800.5 | < 0.02 | < 0.02 | < 0.02 | 1.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 800.5 | 202.14 | 34.728 | 32.20 | 1.36 | 2.20 | < 0.02 | < 0.02 | 100.92 |
16 | 1001.7 | 205.89 | 34.723 | 32.32 | 1.17 | 2.21 | < 0.02 | < 0.02 | 105.89 |
17 | 1001.9 | < 0.02 | < 0.02 | < 0.02 | 1.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1301.7 | 209.33 | 34.712 | 32.70 | 0.91 | 2.25 | < 0.02 | < 0.02 | 113.14 |
14 | 1601.2 | 211.29 | 34.700 | 33.22 | 0.69 | 2.29 | < 0.02 | < 0.02 | 120.14 |
12 | 2000.8 | < 0.02 | < 0.02 | < 0.02 | 0.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 2000.9 | 214.28 | 34.689 | 33.70 | 0.48 | 2.32 | < 0.02 | < 0.02 | 126.77 |
11 | 2401.1 | 219.37 | 34.681 | 33.78 | 0.31 | 2.34 | < 0.02 | < 0.02 | 131.49 |
10 | 2901.4 | 226.83 | 34.672 | 33.80 | 0.13 | 2.33 | < 0.02 | < 0.02 | 135.06 |
9 | 3399.9 | 234.69 | 34.665 | 33.72 | -0.04 | 2.33 | < 0.02 | < 0.02 | 138.19 |
8 | 3900.8 | 242.69 | 34.656 | 33.62 | -0.19 | 2.33 | < 0.02 | < 0.02 | 144.70 |
2 | 3938.7 | < 0.02 | < 0.02 | < 0.02 | -0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3938.9 | < 0.02 | < 0.02 | < 0.02 | -0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3972.4 | < 0.02 | < 0.02 | < 0.02 | -0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 3972.4 | < 0.02 | < 0.02 | < 0.02 | -0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3972.5 | < 0.02 | < 0.02 | < 0.02 | -0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3972.5 | < 0.02 | < 0.02 | < 0.02 | -0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 3972.5 | 242.96 | 34.655 | 33.72 | -0.21 | 2.33 | < 0.02 | < 0.02 | 150.37 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |