Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-23 22:15 to 2021-02-24 00:16 UTC
Where: 66° 15.0' S 65° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.5 | < 0.02 | < 0.02 | < 0.02 | -1.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.5 | < 0.02 | 33.747 | 28.59 | -1.29 | 1.95 | 0.34 | 0.19 | 56.93 |
34 | 29.9 | < 0.02 | 33.769 | 28.70 | -1.29 | 1.96 | 0.37 | 0.19 | 57.49 |
33 | 30 | < 0.02 | < 0.02 | < 0.02 | -1.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 49.7 | < 0.02 | 33.813 | 28.91 | -1.27 | 1.98 | 0.36 | 0.18 | 58.16 |
31 | 49.7 | < 0.02 | < 0.02 | < 0.02 | -1.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 60.3 | < 0.02 | < 0.02 | < 0.02 | -1.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 60.4 | 316.60 | < 0.02 | 30.34 | -1.55 | 2.10 | 0.32 | 0.14 | 63.20 |
28 | 80.3 | 302.94 | < 0.02 | 31.32 | -1.58 | 2.16 | 0.13 | 0.16 | 65.82 |
27 | 80.3 | < 0.02 | < 0.02 | < 0.02 | -1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 129.8 | < 0.02 | < 0.02 | < 0.02 | -1.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 129.9 | 293.56 | 34.370 | 31.73 | -1.36 | 2.19 | < 0.02 | 0.04 | 68.82 |
23 | 200.3 | < 0.02 | < 0.02 | < 0.02 | -0.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 200.4 | 271.23 | 34.465 | 32.17 | -0.79 | 2.21 | < 0.02 | < 0.02 | 76.62 |
22 | 349.8 | 236.70 | 34.607 | 32.70 | 0.21 | 2.24 | 0.03 | < 0.02 | 90.82 |
21 | 349.8 | < 0.02 | < 0.02 | < 0.02 | 0.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 550.6 | 219.46 | 34.679 | 32.42 | 0.66 | 2.25 | < 0.02 | < 0.02 | 102.91 |
19 | 550.6 | < 0.02 | < 0.02 | < 0.02 | 0.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 750.2 | 216.47 | 34.689 | 32.66 | 0.64 | 2.27 | < 0.02 | < 0.02 | 110.75 |
18 | 750.2 | < 0.02 | < 0.02 | < 0.02 | 0.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 949.9 | 215.13 | 34.691 | 32.95 | 0.57 | 2.30 | < 0.02 | < 0.02 | 117.49 |
15 | 949.9 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1150.3 | 218.84 | 34.683 | 33.06 | 0.41 | 2.31 | < 0.02 | < 0.02 | 119.20 |
13 | 1500 | 223.04 | 34.676 | 33.11 | 0.22 | 2.32 | < 0.02 | < 0.02 | 126.48 |
12 | 1800.3 | 228.13 | 34.670 | 33.06 | 0.08 | 2.33 | < 0.02 | < 0.02 | 128.27 |
11 | 2001.4 | 231.48 | 34.665 | 32.98 | -0.01 | 2.32 | < 0.02 | < 0.02 | 127.62 |
10 | 2100.7 | 238.85 | 34.655 | 32.81 | -0.11 | 2.31 | < 0.02 | < 0.02 | 122.78 |
9 | 2200.5 | 241.17 | 34.653 | 32.84 | -0.17 | 2.31 | < 0.02 | < 0.02 | 123.12 |
8 | 2349.4 | 247.24 | < 0.02 | 32.78 | -0.28 | 2.30 | < 0.02 | < 0.02 | 119.90 |
2 | 2486.3 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2486.4 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2510.9 | 250.68 | 34.639 | 32.78 | -0.32 | 2.30 | < 0.02 | < 0.02 | 117.55 |
7 | 2511 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 2511 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2511 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2511 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |