Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-23 16:49 to 2021-02-23 18:41 UTC
Where: 66° 24.1' S 65° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.4 | < 0.02 | < 0.02 | < 0.02 | -1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.5 | 360.77 | 33.636 | 28.17 | -1.51 | 1.94 | 0.65 | 0.22 | 56.55 |
33 | 29.9 | < 0.02 | < 0.02 | < 0.02 | -1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 29.9 | 359.66 | 33.639 | 28.32 | -1.52 | 1.95 | 0.68 | 0.21 | 56.56 |
31 | 60.2 | < 0.02 | < 0.02 | < 0.02 | -1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 60.3 | 358.90 | 33.639 | 28.30 | -1.56 | 1.96 | 0.70 | 0.21 | 56.93 |
29 | 80.2 | < 0.02 | < 0.02 | < 0.02 | -1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 80.3 | 341.79 | < 0.02 | 28.74 | -1.46 | 2.00 | 0.76 | 0.18 | 58.48 |
27 | 120.1 | < 0.02 | < 0.02 | < 0.02 | -1.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 120.1 | 299.81 | 34.293 | 31.46 | -1.49 | 2.15 | 0.13 | 0.16 | 65.77 |
26 | 160 | 288.96 | 34.376 | 31.91 | -1.20 | 2.18 | 0.03 | 0.06 | 70.08 |
25 | 160 | < 0.02 | < 0.02 | < 0.02 | -1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 300 | < 0.02 | < 0.02 | < 0.02 | -0.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 300.1 | 273.33 | 34.527 | 31.92 | -0.56 | 2.20 | < 0.02 | 0.04 | 77.41 |
21 | 519.8 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 519.8 | 221.03 | 34.672 | 32.47 | 0.66 | 2.23 | < 0.02 | 0.02 | 100.49 |
19 | 749.4 | < 0.02 | < 0.02 | < 0.02 | 0.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 749.5 | 227.15 | 34.666 | 32.24 | 0.40 | 2.26 | < 0.02 | 0.02 | 105.12 |
17 | 1000.2 | < 0.02 | < 0.02 | < 0.02 | 0.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 1000.3 | 219.82 | 34.679 | 33.08 | 0.40 | 2.29 | < 0.02 | 0.02 | 118.08 |
15 | 1099.3 | < 0.02 | < 0.02 | < 0.02 | 0.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1099.3 | 231.12 | < 0.02 | 32.68 | 0.18 | 2.29 | < 0.02 | 0.03 | 112.36 |
14 | 1250.1 | 222.55 | 34.675 | 33.25 | 0.26 | 2.31 | < 0.02 | 0.03 | 122.78 |
13 | 1250.1 | < 0.02 | < 0.02 | < 0.02 | 0.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 1449.7 | < 0.02 | < 0.02 | < 0.02 | -0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1449.8 | 237.55 | 34.655 | 32.94 | 0.00 | 2.29 | < 0.02 | 0.03 | 115.02 |
10 | 1650.3 | 228.75 | 34.671 | 33.38 | 0.06 | 2.32 | < 0.02 | 0.03 | 128.62 |
9 | 1850.8 | 238.94 | 34.656 | 33.11 | -0.12 | 2.30 | < 0.02 | 0.02 | 122.08 |
8 | 2100.1 | 250.95 | 34.639 | 32.93 | -0.33 | 2.29 | < 0.02 | 0.02 | 116.07 |
2 | 2157.6 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 2157.7 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2182.6 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2182.7 | 251.62 | 34.636 | 32.83 | -0.35 | 2.29 | < 0.02 | 0.02 | 114.75 |
4 | 2183.6 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2183.6 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2183.7 | < 0.02 | < 0.02 | < 0.02 | -0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |