Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-23 12:05 to 2021-02-23 14:26 UTC
Where: 66° 33.2' S 65° 01.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.2 | < 0.02 | < 0.02 | < 0.02 | -1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.3 | 362.42 | 33.637 | 27.97 | -1.52 | 1.92 | 0.60 | 0.21 | 56.40 |
34 | 19.8 | 362.38 | 33.640 | 28.01 | -1.53 | 1.92 | 0.61 | 0.20 | 56.31 |
33 | 40.4 | < 0.02 | < 0.02 | 27.92 | -1.54 | 1.94 | 0.62 | 0.20 | 56.20 |
32 | 60.5 | < 0.02 | < 0.02 | 27.92 | -1.51 | 1.93 | 0.61 | 0.20 | 56.23 |
31 | 81.1 | 320.93 | 34.071 | 30.19 | -1.59 | 2.08 | 0.34 | 0.15 | 62.64 |
30 | 81.1 | < 0.02 | < 0.02 | < 0.02 | -1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 99.9 | 302.18 | 34.293 | 31.50 | -1.77 | 2.15 | 0.03 | 0.12 | 65.84 |
28 | 120.5 | 302.67 | 34.320 | 31.54 | -1.76 | 2.15 | < 0.02 | 0.05 | 65.68 |
27 | 145.2 | 303.11 | 34.341 | 31.34 | -1.71 | 2.15 | < 0.02 | 0.03 | 65.66 |
26 | 170.1 | < 0.02 | < 0.02 | 31.41 | -1.61 | 2.16 | < 0.02 | 0.03 | 66.55 |
25 | 200.8 | 294.27 | 34.387 | 31.50 | -1.44 | 2.17 | < 0.02 | 0.03 | 68.50 |
24 | 280.5 | 248.85 | 34.532 | 32.35 | -0.05 | 2.24 | < 0.02 | 0.03 | 80.03 |
23 | 380.4 | 222.55 | 34.638 | 32.32 | 0.66 | 2.23 | < 0.02 | 0.02 | 90.05 |
22 | 485.7 | 211.78 | 34.693 | 32.16 | 1.02 | 2.22 | < 0.02 | 0.02 | 97.46 |
21 | 485.7 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 600.3 | 217.41 | 34.684 | 32.23 | 0.79 | 2.23 | < 0.02 | 0.02 | 100.79 |
18 | 800.7 | < 0.02 | < 0.02 | < 0.02 | 0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 800.7 | 216.92 | 34.689 | 32.60 | 0.67 | 2.25 | < 0.02 | < 0.02 | 108.73 |
16 | 1049.6 | < 0.02 | < 0.02 | < 0.02 | 0.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 1049.7 | 217.54 | 34.685 | 33.00 | 0.49 | 2.29 | < 0.02 | < 0.02 | 117.51 |
15 | 1300.2 | < 0.02 | < 0.02 | < 0.02 | 0.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1600.6 | 227.41 | 34.671 | 33.25 | 0.13 | 2.31 | < 0.02 | < 0.02 | 124.81 |
12 | 1950.9 | < 0.02 | < 0.02 | < 0.02 | -0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1950.9 | 241.53 | 34.653 | 32.89 | -0.16 | 2.29 | < 0.02 | 0.02 | 120.19 |
10 | 2000.8 | < 0.02 | < 0.02 | < 0.02 | -0.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 2000.8 | 249.07 | 34.640 | 32.70 | -0.28 | 2.28 | < 0.02 | 0.02 | 114.09 |
8 | 2100.8 | < 0.02 | < 0.02 | < 0.02 | -0.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 2100.8 | 248.99 | 34.642 | 32.72 | -0.30 | 2.28 | < 0.02 | 0.02 | 116.16 |
1 | 2267.1 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 2270.3 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 2291.7 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 2291.8 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 2291.8 | 254.48 | 34.633 | 32.66 | -0.39 | 2.28 | < 0.02 | 0.03 | 113.03 |
4 | 2291.8 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 2291.8 | < 0.02 | < 0.02 | < 0.02 | -0.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |