Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-20 18:58 to 2021-02-20 20:30 UTC
Where: 66° 33.4' S 60° 14.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.7 | < 0.02 | < 0.02 | < 0.02 | -1.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.7 | 362.42 | 33.627 | 28.11 | -1.63 | 1.93 | 0.58 | 0.21 | 55.82 |
34 | 20.5 | 362.25 | 33.648 | 27.92 | -1.60 | 1.90 | 0.57 | 0.21 | 55.37 |
33 | 20.6 | < 0.02 | < 0.02 | < 0.02 | -1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 45.6 | 362.69 | < 0.02 | 27.83 | -1.62 | 1.90 | 0.57 | 0.21 | 54.71 |
31 | 45.6 | < 0.02 | < 0.02 | < 0.02 | -1.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 65.2 | < 0.02 | < 0.02 | < 0.02 | -1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 65.2 | 359.97 | 33.686 | 27.96 | -1.61 | 1.90 | 0.64 | 0.20 | 55.17 |
28 | 89.6 | 324.77 | < 0.02 | 29.25 | -1.44 | 2.06 | 1.08 | 0.15 | 61.63 |
27 | 89.6 | < 0.02 | < 0.02 | < 0.02 | -1.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 120.3 | < 0.02 | < 0.02 | < 0.02 | -1.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 120.3 | 321.60 | 34.289 | 29.69 | -1.40 | 2.08 | 0.96 | 0.13 | 62.81 |
24 | 180.2 | 314.59 | < 0.02 | 30.63 | -1.46 | 2.12 | 0.61 | 0.12 | 65.49 |
23 | 180.2 | < 0.02 | < 0.02 | < 0.02 | -1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 240.6 | < 0.02 | < 0.02 | < 0.02 | -1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 240.6 | 315.08 | 34.363 | 31.23 | -1.74 | 2.12 | < 0.02 | 0.09 | 65.20 |
20 | 300.7 | < 0.02 | < 0.02 | < 0.02 | -1.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 400.3 | < 0.02 | < 0.02 | < 0.02 | -0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 400.4 | 274.75 | 34.522 | 31.99 | -0.67 | 2.18 | < 0.02 | 0.03 | 77.40 |
17 | 550.6 | 238.71 | 34.629 | 32.29 | 0.18 | 2.20 | < 0.02 | 0.02 | 94.03 |
15 | 750.5 | < 0.02 | < 0.02 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 750.5 | 223.93 | 34.672 | < 0.02 | 0.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1000.3 | < 0.02 | < 0.02 | < 0.02 | 0.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1000.4 | 222.99 | 34.675 | 33.10 | 0.33 | 2.28 | < 0.02 | 0.02 | 115.75 |
11 | 1199.9 | < 0.02 | < 0.02 | < 0.02 | 0.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 1200 | 227.46 | 34.670 | 33.31 | 0.19 | 2.28 | < 0.02 | 0.02 | 118.79 |
9 | 1400 | < 0.02 | < 0.02 | < 0.02 | 0.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 1400.1 | 235.18 | 34.659 | 33.14 | 0.03 | 2.27 | < 0.02 | 0.02 | 115.61 |
8 | 1500.4 | 235.90 | 34.659 | 33.17 | 0.01 | 2.27 | < 0.02 | 0.03 | 115.84 |
1 | 1591.1 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1591.1 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1617.7 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 1617.7 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1617.7 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 1617.7 | 236.44 | 34.661 | 33.19 | 0.01 | 2.27 | < 0.02 | 0.02 | 116.20 |
5 | 1617.8 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |