Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-19 13:51 to 2021-02-19 17:06 UTC
Where: 65° 30.2' S 59° 59.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 10.5 | 350.63 | 33.622 | 26.29 | -0.86 | 1.79 | 0.41 | 0.23 | 43.74 |
35 | 10.7 | < 0.02 | < 0.02 | < 0.02 | -0.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20.1 | < 0.02 | < 0.02 | < 0.02 | -0.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20.2 | 350.86 | 33.614 | 26.20 | -0.86 | 1.83 | 0.44 | 0.23 | 43.40 |
32 | 30.2 | 336.92 | 33.785 | 27.41 | -0.95 | 1.88 | 0.35 | 0.21 | 48.27 |
31 | 45.4 | 283.91 | 34.262 | 31.43 | -0.84 | 2.17 | 0.09 | 0.12 | 65.02 |
30 | 45.5 | < 0.02 | < 0.02 | < 0.02 | -0.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 65.1 | 250.19 | 34.376 | 32.90 | 0.12 | 2.27 | 0.04 | 0.08 | 72.87 |
28 | 90.7 | 219.91 | 34.488 | 33.96 | 0.66 | 2.34 | < 0.02 | 0.04 | 79.89 |
27 | 120.7 | 201.91 | 34.562 | 34.35 | 1.16 | 2.37 | < 0.02 | 0.02 | 85.32 |
26 | 150.2 | 196.55 | 34.593 | 34.13 | 1.27 | 2.35 | < 0.02 | 0.02 | 86.93 |
25 | 191.1 | 187.93 | 34.641 | 33.84 | 1.55 | 2.34 | < 0.02 | 0.02 | 90.30 |
23 | 240.6 | < 0.02 | < 0.02 | < 0.02 | 1.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 240.6 | 183.65 | 34.683 | 33.49 | 1.73 | 2.30 | < 0.02 | 0.02 | 92.27 |
22 | 320.4 | 188.87 | 34.700 | 32.88 | 1.64 | 2.26 | < 0.02 | 0.02 | 92.97 |
21 | 401.1 | 191.95 | 34.713 | 32.51 | 1.61 | 2.23 | < 0.02 | 0.02 | 94.82 |
20 | 630.3 | < 0.02 | < 0.02 | < 0.02 | 1.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 630.4 | 200.26 | 34.724 | 31.97 | 1.37 | 2.19 | < 0.02 | 0.02 | 99.68 |
18 | 801 | 205.57 | 34.721 | 31.82 | 1.20 | 2.19 | < 0.02 | < 0.02 | 102.68 |
17 | 1101 | 208.25 | 34.712 | 32.22 | 0.93 | 2.23 | < 0.02 | < 0.02 | 111.52 |
16 | 1501.6 | 212.05 | 34.696 | 32.74 | 0.63 | 2.27 | < 0.02 | < 0.02 | 119.96 |
15 | 2001.3 | 216.16 | 34.684 | 33.13 | 0.39 | 2.31 | < 0.02 | < 0.02 | 127.54 |
14 | 2500.4 | 224.73 | 34.674 | 33.11 | 0.18 | 2.31 | < 0.02 | < 0.02 | 130.77 |
12 | 3001.5 | < 0.02 | < 0.02 | < 0.02 | 0.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 3001.7 | 232.19 | 34.665 | 33.07 | 0.01 | 2.31 | < 0.02 | < 0.02 | 132.94 |
11 | 3151.1 | 242.33 | < 0.02 | 32.65 | -0.10 | 2.28 | < 0.02 | 0.02 | 121.31 |
10 | 3549.3 | 251.66 | 34.647 | 32.41 | -0.23 | 2.26 | < 0.02 | 0.02 | 117.15 |
9 | 3600.2 | 243.31 | 34.656 | 32.85 | -0.19 | 2.30 | < 0.02 | 0.02 | 136.04 |
8 | 3799.7 | 256.76 | 34.649 | 32.33 | -0.32 | 2.26 | < 0.02 | 0.02 | 117.89 |
1 | 3852.8 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3855.9 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3873.9 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 3873.9 | 257.56 | 34.649 | 32.29 | -0.32 | 2.25 | < 0.02 | 0.02 | 116.98 |
6 | 3874 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3874.1 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3874.2 | < 0.02 | < 0.02 | < 0.02 | -0.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |