Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-19 05:17 to 2021-02-19 08:53 UTC
Where: 65° 00.0' S 60° 00.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 0.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.7 | 354.03 | 33.439 | 23.83 | 0.07 | 1.59 | 0.58 | 0.29 | 29.79 |
34 | 15.3 | 353.58 | 33.446 | 23.80 | 0.06 | 1.59 | 0.57 | 0.29 | 29.52 |
33 | 29.7 | 344.60 | 33.949 | 27.81 | -1.08 | 2.00 | 0.62 | 0.24 | 41.99 |
32 | 45.2 | 331.61 | 34.055 | 29.28 | -1.54 | 2.05 | 0.37 | 0.24 | 49.67 |
31 | 45.3 | < 0.02 | < 0.02 | < 0.02 | -1.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 59 | 311.20 | 34.133 | 30.62 | -1.19 | 2.13 | 0.22 | 0.26 | 55.19 |
29 | 75.2 | 273.68 | 34.242 | 32.62 | -0.44 | 2.25 | 0.09 | 0.16 | 63.82 |
28 | 90 | 222.05 | 34.403 | 34.82 | 0.70 | 2.39 | < 0.02 | 0.05 | 75.70 |
27 | 130.1 | 186.15 | 34.550 | 35.68 | 1.59 | 2.45 | < 0.02 | 0.02 | 85.14 |
26 | 190.2 | 179.05 | 34.624 | 35.01 | 1.76 | 2.40 | < 0.02 | 0.02 | 89.32 |
25 | 250 | 179.05 | 34.659 | 34.43 | 1.82 | 2.36 | < 0.02 | < 0.02 | 90.16 |
24 | 250 | < 0.02 | < 0.02 | < 0.02 | 1.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 350 | 183.51 | 34.692 | 33.48 | 1.81 | 2.29 | < 0.02 | < 0.02 | 90.88 |
22 | 450 | < 0.02 | < 0.02 | 32.72 | 1.73 | 2.24 | < 0.02 | < 0.02 | 92.86 |
21 | 550.2 | 193.74 | 34.724 | 32.28 | 1.66 | 2.22 | < 0.02 | < 0.02 | 94.12 |
20 | 650.2 | < 0.02 | < 0.02 | < 0.02 | 1.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 750.4 | 201.56 | 34.734 | 31.69 | 1.48 | 2.18 | < 0.02 | < 0.02 | 97.34 |
17 | 850.8 | < 0.02 | < 0.02 | < 0.02 | 1.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 850.9 | 203.43 | 34.731 | 31.74 | 1.37 | 2.18 | < 0.02 | < 0.02 | 100.14 |
16 | 1100.9 | 206.87 | 34.720 | 32.14 | 1.10 | 2.22 | < 0.02 | < 0.02 | 107.39 |
15 | 1401.4 | 209.82 | 34.706 | 32.75 | 0.82 | 2.26 | < 0.02 | 0.02 | 115.17 |
14 | 1701.9 | 211.56 | 34.696 | 33.22 | 0.63 | 2.30 | < 0.02 | < 0.02 | 121.54 |
13 | 2001.8 | 214.15 | 34.688 | 33.52 | 0.47 | 2.32 | < 0.02 | 0.02 | 126.06 |
12 | 2402.3 | 220.71 | 34.679 | 33.52 | 0.29 | 2.32 | < 0.02 | 0.02 | 129.17 |
11 | 2801.6 | 226.57 | 34.672 | 33.45 | 0.15 | 2.32 | < 0.02 | < 0.02 | 131.40 |
10 | 3300.1 | 234.16 | 34.664 | 33.38 | -0.02 | 2.31 | < 0.02 | < 0.02 | 133.67 |
9 | 3801.2 | 245.68 | 34.653 | 33.12 | -0.20 | 2.29 | < 0.02 | < 0.02 | 131.65 |
8 | 4051.3 | 255.91 | 34.645 | 32.79 | -0.32 | 2.27 | < 0.02 | < 0.02 | 121.69 |
1 | 4095.9 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 4098.5 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 4121.5 | 262.87 | 34.643 | 32.45 | -0.36 | 2.25 | < 0.02 | < 0.02 | 108.93 |
4 | 4121.5 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 4121.5 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 4121.6 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 4121.9 | < 0.02 | < 0.02 | < 0.02 | -0.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |