Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-15 04:53 to 2021-02-15 06:23 UTC
Where: 63° 00.0' S 55° 00.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.3 | 346.66 | 33.790 | 25.55 | 1.56 | 1.67 | 0.19 | 0.36 | 33.66 |
33 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 1.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20.7 | 346.52 | 33.790 | 25.52 | 1.56 | 1.66 | 0.18 | 0.36 | 33.58 |
32 | 39.9 | 351.35 | 33.803 | 25.73 | 1.50 | 1.69 | 0.19 | 0.34 | 34.41 |
31 | 39.9 | < 0.02 | < 0.02 | < 0.02 | 1.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 55 | < 0.02 | < 0.02 | < 0.02 | -0.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 55.3 | < 0.02 | < 0.02 | < 0.02 | -0.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 55.3 | 368.90 | 33.867 | 26.62 | -0.68 | 1.82 | 0.26 | 0.26 | 37.73 |
26 | 71.7 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 71.8 | 346.97 | 34.004 | 28.63 | -1.60 | 1.99 | 0.36 | 0.27 | 45.43 |
24 | 91.5 | < 0.02 | < 0.02 | < 0.02 | -1.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 91.6 | 323.75 | 34.106 | 30.01 | -1.30 | 2.09 | 0.26 | 0.27 | 51.88 |
23 | 120.1 | 236.48 | 34.369 | 34.60 | 0.55 | 2.39 | < 0.02 | 0.11 | 72.43 |
22 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 150.4 | < 0.02 | < 0.02 | < 0.02 | 1.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 150.4 | 195.75 | 34.504 | 35.92 | 1.43 | 2.47 | < 0.02 | 0.03 | 81.63 |
18 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 1.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 200.7 | 183.82 | 34.581 | 35.64 | 1.69 | 2.45 | < 0.02 | < 0.02 | 85.98 |
15 | 271.1 | < 0.02 | < 0.02 | < 0.02 | 1.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 271.1 | 177.84 | 34.642 | 35.02 | 1.85 | 2.41 | < 0.02 | < 0.02 | 88.56 |
16 | 271.2 | < 0.02 | < 0.02 | < 0.02 | 1.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 400.7 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 400.8 | 183.47 | 34.687 | 33.93 | 1.80 | 2.33 | < 0.02 | < 0.02 | 91.08 |
11 | 751.2 | < 0.02 | < 0.02 | < 0.02 | 1.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 751.3 | 197.85 | 34.730 | 32.30 | 1.57 | 2.22 | < 0.02 | < 0.02 | 95.71 |
9 | 1100.4 | < 0.02 | < 0.02 | < 0.02 | 1.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 1100.5 | 206.20 | 34.729 | 32.10 | 1.27 | 2.21 | < 0.02 | < 0.02 | 102.65 |
6 | 1500.8 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 1500.8 | 209.59 | 34.710 | 32.89 | 0.89 | 2.27 | < 0.02 | < 0.02 | 113.42 |
4 | 1500.9 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1500.9 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1500.9 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1501 | < 0.02 | < 0.02 | < 0.02 | 0.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1501 | < 0.02 | < 0.02 | < 0.02 | 0.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1501 | < 0.02 | < 0.02 | < 0.02 | 0.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |