Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-13 20:34 to 2021-02-14 00:02 UTC
Where: 65° 00.0' S 55° 00.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.1 | 348.76 | 33.899 | 26.64 | -0.03 | 1.76 | 0.08 | 0.30 | 42.82 |
35 | 20.6 | 348.62 | 33.899 | 26.62 | -0.02 | 1.75 | 0.06 | 0.30 | 42.75 |
34 | 40.8 | 348.58 | 33.900 | 26.62 | -0.02 | 1.76 | 0.07 | 0.29 | 42.86 |
33 | 65.5 | 293.02 | 34.280 | 31.19 | -0.86 | 2.18 | 0.22 | 0.18 | 65.27 |
32 | 90.1 | 246.98 | 34.434 | 33.36 | 0.14 | 2.30 | 0.02 | 0.15 | 75.80 |
31 | 120.7 | 232.42 | 34.497 | 33.77 | 0.17 | 2.32 | < 0.02 | 0.05 | 79.56 |
30 | 200.7 | 196.78 | 34.629 | 34.06 | 1.28 | 2.34 | < 0.02 | < 0.02 | 89.96 |
29 | 300 | 192.09 | 34.686 | 33.27 | 1.48 | 2.29 | < 0.02 | < 0.02 | 94.09 |
28 | 450.1 | 196.55 | 34.709 | 32.64 | 1.44 | 2.25 | < 0.02 | 0.02 | 96.78 |
27 | 600.3 | 200.57 | 34.720 | 32.30 | 1.33 | 2.23 | < 0.02 | 0.02 | 100.43 |
26 | 749.9 | 208.39 | 34.707 | 32.27 | 1.07 | 2.23 | < 0.02 | 0.02 | 102.76 |
25 | 1000.9 | 212.18 | 34.701 | 32.55 | 0.83 | 2.26 | < 0.02 | 0.02 | 109.52 |
24 | 1250.6 | 214.95 | 34.692 | 32.96 | 0.63 | 2.29 | < 0.02 | 0.02 | 114.49 |
23 | 1266.1 | < 0.02 | < 0.02 | < 0.02 | 0.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 1281.2 | < 0.02 | < 0.02 | < 0.02 | 0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 1287 | < 0.02 | < 0.02 | < 0.02 | 0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 1289 | < 0.02 | < 0.02 | < 0.02 | 0.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 1291.8 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 1294.4 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 1296.7 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 1299.5 | < 0.02 | < 0.02 | < 0.02 | 0.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 1500.7 | 220.58 | 34.678 | 33.13 | 0.42 | 2.30 | < 0.02 | 0.02 | 116.76 |
15 | 1500.8 | < 0.02 | < 0.02 | < 0.02 | 0.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 1750.8 | 223.84 | 34.672 | 33.34 | 0.27 | 2.31 | < 0.02 | 0.03 | 121.54 |
12 | 2001.1 | 225.67 | 34.671 | 33.45 | 0.18 | 2.32 | < 0.02 | 0.02 | 125.31 |
11 | 2400.7 | 231.84 | 34.666 | 33.45 | 0.02 | 2.32 | < 0.02 | 0.02 | 128.88 |
10 | 2800.4 | 240.14 | 34.658 | 33.26 | -0.11 | 2.30 | < 0.02 | < 0.02 | 124.76 |
9 | 3200.7 | 248.40 | 34.653 | 33.12 | -0.23 | 2.29 | < 0.02 | 0.02 | 123.25 |
8 | 3600.3 | 254.97 | 34.649 | 32.78 | -0.31 | 2.28 | < 0.02 | < 0.02 | 118.75 |
2 | 3696.7 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 3696.7 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 3697.2 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3697.2 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 3697.2 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 3697.3 | 255.51 | 34.649 | 32.76 | -0.31 | 2.28 | < 0.02 | 0.02 | 118.27 |
7 | 3697.4 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |