Deployment Details
Survey: - IN2021_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CDOM CTD 25 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Conductivity CTD 24 - SN 4774,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 1794,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-2009DR
When: 2021-02-13 12:24 to 2021-02-13 13:43 UTC
Where: 65° 31.5' S 55° 03.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5 | 361.58 | 33.449 | 26.29 | -1.54 | 1.74 | 0.09 | 0.21 | 48.26 |
36 | 5.1 | < 0.02 | < 0.02 | < 0.02 | -1.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 14.9 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 15 | 360.86 | 33.471 | 26.35 | -1.60 | 1.77 | 0.12 | 0.21 | 48.66 |
32 | 30.1 | < 0.02 | < 0.02 | < 0.02 | -1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 30.2 | 352.20 | 33.590 | 27.11 | -1.61 | 1.84 | 0.29 | 0.20 | 51.52 |
29 | 45.5 | 333.44 | 33.850 | 28.59 | -1.73 | 1.99 | 0.69 | 0.16 | 58.44 |
30 | 45.5 | < 0.02 | < 0.02 | < 0.02 | -1.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 54.9 | 326.47 | 33.963 | 29.24 | -1.76 | 2.04 | 0.67 | 0.15 | 60.30 |
28 | 55 | < 0.02 | < 0.02 | < 0.02 | -1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 75.8 | 317.94 | 34.152 | 30.32 | -1.77 | 2.09 | 0.38 | 0.15 | 62.52 |
26 | 75.9 | < 0.02 | < 0.02 | < 0.02 | -1.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 99.6 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 99.7 | 315.84 | 34.219 | 30.70 | -1.78 | 2.10 | 0.17 | 0.16 | 62.77 |
20 | 199.7 | 310.80 | 34.317 | 31.06 | -1.74 | 2.12 | < 0.02 | < 0.02 | 64.75 |
22 | 199.8 | < 0.02 | < 0.02 | < 0.02 | -1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 199.8 | < 0.02 | < 0.02 | < 0.02 | -1.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 300.6 | 310.75 | 34.343 | 31.07 | -1.76 | 2.13 | < 0.02 | < 0.02 | 63.99 |
19 | 300.7 | < 0.02 | < 0.02 | < 0.02 | -1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 400.2 | < 0.02 | < 0.02 | < 0.02 | -1.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 400.2 | 289.27 | 34.410 | 31.68 | -1.19 | 2.18 | < 0.02 | < 0.02 | 70.51 |
14 | 499.6 | 277.21 | 34.480 | 31.86 | -0.86 | 2.20 | < 0.02 | < 0.02 | 78.32 |
15 | 499.6 | < 0.02 | < 0.02 | < 0.02 | -0.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 600.2 | 258.01 | 34.559 | 32.16 | -0.35 | 2.21 | < 0.02 | < 0.02 | 86.75 |
11 | 749.8 | 240.19 | 34.626 | 32.58 | 0.05 | 2.24 | < 0.02 | < 0.02 | 100.06 |
12 | 749.9 | < 0.02 | < 0.02 | < 0.02 | 0.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 799.6 | 237.91 | 34.633 | 32.68 | 0.08 | 2.24 | < 0.02 | < 0.02 | 102.44 |
9 | 899.5 | 231.43 | 34.655 | 32.99 | 0.16 | 2.27 | < 0.02 | < 0.02 | 110.74 |
8 | 899.5 | < 0.02 | < 0.02 | < 0.02 | 0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 945.7 | < 0.02 | < 0.02 | < 0.02 | 0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 945.8 | < 0.02 | < 0.02 | < 0.02 | 0.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 960.8 | < 0.02 | < 0.02 | < 0.02 | 0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 960.9 | 231.52 | 34.655 | 32.95 | 0.17 | 2.27 | < 0.02 | < 0.02 | 110.57 |
5 | 960.9 | < 0.02 | < 0.02 | < 0.02 | 0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 960.9 | < 0.02 | < 0.02 | < 0.02 | 0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 960.9 | < 0.02 | < 0.02 | < 0.02 | 0.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
CDOM CTD 25 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
Conductivity CTD 24 - SN 4774 | Seabird | SBE4C | 4774 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-2009DR | WET Labs | C-Star | CST-2009DR | Transmittance (%) |