Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 23 - SN 1312,Conductivity CTD 23 - SN 2312,Fluorometer - CTD 23 - WET Labs ECO FLNTU,Licor - CTD 23 - SN 70111,Oxygen CTD 23-SBE 43-SN 3154,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 23 - WET Labs ECO FLNTU,Temperature CTD 23 - SN 4522
When: 2019-04-13 04:05 to 2019-04-13 04:17 UTC
Where: 39° 05.7' S 146° 43.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 2032 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2029 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2031 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2022 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2025 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2030 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2034 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2018 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2033 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2019 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2020 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2028 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2024 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2021 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2035 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2026 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2036 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2023 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2027 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2017 | 13.9 | 232.73 | 35.761 | 0.11 | 17.61 | 0.18 | 0.05 | 0.04 | 0.89 |
| 2016 | 16.3 | 236.97 | 35.761 | 0.12 | 17.61 | 0.17 | 0.06 | 0.04 | 0.87 |
| 2015 | 18.4 | 237.24 | 35.762 | 0.11 | 17.61 | 0.17 | 0.06 | 0.04 | 0.83 |
| 1214 | 20.3 | 237.02 | 35.762 | 0.11 | 17.61 | 0.17 | 0.05 | 0.04 | 0.86 |
| 2013 | 22 | 237.02 | 35.762 | 0.12 | 17.61 | 0.17 | 0.06 | 0.05 | 0.81 |
| 2012 | 24 | 236.30 | 35.761 | 0.14 | 17.61 | 0.24 | 0.20 | 0.05 | 0.89 |
| 2011 | 26.1 | 236.03 | 35.762 | 0.13 | 17.61 | 0.17 | 0.08 | 0.05 | 0.87 |
| 2010 | 28.2 | 235.85 | 35.762 | 0.13 | 17.61 | 0.17 | 0.08 | 0.05 | 0.86 |
| 2009 | 30.1 | 235.18 | 35.761 | 0.13 | 17.61 | 0.17 | 0.09 | 0.05 | 0.87 |
| 12001 | 31.2 | 235.63 | 35.762 | 0.14 | 17.61 | 0.18 | 0.11 | 0.05 | 0.90 |
| 2008 | 31.4 | 235.81 | 35.762 | 0.14 | 17.61 | 0.24 | 0.14 | 0.06 | 1.00 |
| 2006 | 33.8 | 235.68 | 35.762 | 0.14 | 17.61 | 0.17 | 0.09 | 0.05 | 0.88 |
| 2005 | 36 | 235.85 | 35.761 | 0.15 | 17.61 | 0.18 | 0.10 | 0.05 | 0.88 |
| 12004 | 38.2 | 235.54 | 35.761 | 0.15 | 17.61 | 0.17 | 0.10 | 0.05 | 0.92 |
| 12003 | 40.3 | 235.50 | 35.762 | 0.14 | 17.61 | 0.17 | 0.09 | 0.05 | 0.90 |
| 1269 | 47.2 | 235.54 | 35.761 | 0.15 | 17.61 | 0.17 | 0.10 | 0.05 | 0.86 |
| 12002 | 47.2 | 247.56 | 35.762 | 0.15 | 17.61 | 0.17 | 0.10 | 0.05 | 0.88 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
| CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
| Conductivity CTD 23 - SN 2312 | Seabird | SBE4C | 2312 | |
| Fluorometer - CTD 23 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
| Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 23-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
| Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 23 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
| Temperature CTD 23 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |