Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 23 - SN 1312,Conductivity CTD 23 - SN 2312,Fluorometer - CTD 23 - WET Labs ECO FLNTU,Licor - CTD 23 - SN 70111,Oxygen CTD 23-SBE 43-SN 3154,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 23 - WET Labs ECO FLNTU,Temperature CTD 23 - SN 4522
When: 2019-04-11 21:08 to 2019-04-11 22:32 UTC
Where: 43° 03.4' S 148° 41.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 2031 | 1999.7 | < 0.02 | < 0.02 | 33.67 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.02 |
| 2030 | 1999.7 | < 0.02 | < 0.02 | 33.67 | 2.33 | 2.33 | < 0.02 | < 0.02 | 88.03 |
| 2024 | 1999.8 | < 0.02 | < 0.02 | 33.66 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.13 |
| 2011 | 1999.9 | 178.02 | 34.677 | 33.60 | 2.34 | 2.34 | < 0.02 | < 0.02 | 87.96 |
| 2005 | 2000 | 178.02 | 34.678 | 33.60 | 2.34 | 2.34 | < 0.02 | < 0.02 | 87.89 |
| 2010 | 2000 | 177.88 | 34.677 | 33.66 | 2.34 | 2.34 | < 0.02 | < 0.02 | 87.91 |
| 2012 | 2000.1 | < 0.02 | < 0.02 | 27.69 | 2.34 | 1.92 | < 0.02 | < 0.02 | 60.55 |
| 2018 | 2000.1 | < 0.02 | < 0.02 | 33.64 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.02 |
| 2016 | 2000.1 | < 0.02 | < 0.02 | 33.66 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.02 |
| 2036 | 2000.1 | < 0.02 | < 0.02 | 33.71 | 2.33 | 2.33 | < 0.02 | < 0.02 | 87.91 |
| 2020 | 2000.2 | < 0.02 | < 0.02 | 33.62 | 2.33 | 2.33 | < 0.02 | < 0.02 | 88.13 |
| 2017 | 2000.2 | < 0.02 | < 0.02 | 33.68 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.08 |
| 2006 | 2000.2 | 177.93 | 34.678 | 33.58 | 2.34 | 2.34 | < 0.02 | < 0.02 | 87.84 |
| 2029 | 2000.2 | < 0.02 | < 0.02 | 33.56 | 2.33 | 2.33 | < 0.02 | < 0.02 | 87.89 |
| 12002 | 2000.2 | 178.20 | 34.678 | 33.59 | 2.34 | 2.34 | < 0.02 | < 0.02 | 87.90 |
| 2035 | 2000.2 | < 0.02 | < 0.02 | 33.66 | 2.33 | 2.33 | < 0.02 | < 0.02 | 87.91 |
| 2027 | 2000.2 | < 0.02 | < 0.02 | 33.58 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.01 |
| 12004 | 2000.2 | 178.15 | 34.678 | 33.62 | 2.34 | 2.33 | < 0.02 | < 0.02 | 87.91 |
| 2019 | 2000.2 | < 0.02 | < 0.02 | 33.58 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.99 |
| 2025 | 2000.2 | < 0.02 | < 0.02 | 33.62 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.10 |
| 2023 | 2000.3 | < 0.02 | < 0.02 | 33.68 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.33 |
| 2015 | 2000.3 | 178.06 | 34.678 | 33.61 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.95 |
| 2021 | 2000.3 | < 0.02 | < 0.02 | 33.61 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.12 |
| 12003 | 2000.3 | 178.06 | 34.678 | 33.59 | 2.34 | 2.34 | < 0.02 | < 0.02 | 88.12 |
| 2032 | 2000.4 | < 0.02 | < 0.02 | 33.67 | 2.33 | 2.33 | < 0.02 | < 0.02 | 88.00 |
| 2009 | 2000.4 | 178.02 | 34.677 | 33.66 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.94 |
| 2013 | 2000.4 | 177.93 | 34.677 | 33.61 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.88 |
| 2028 | 2000.5 | < 0.02 | < 0.02 | 33.58 | 2.33 | 2.33 | < 0.02 | < 0.02 | 88.08 |
| 2026 | 2000.5 | < 0.02 | < 0.02 | 33.61 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.13 |
| 1214 | 2000.5 | 177.97 | 34.677 | 33.58 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.91 |
| 9057 | 2000.5 | 178.33 | 34.618 | 32.56 | 2.34 | 2.27 | < 0.02 | < 0.02 | 72.83 |
| 12001 | 2000.6 | 178.06 | 34.677 | 33.64 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.95 |
| 2034 | 2000.6 | < 0.02 | < 0.02 | 33.68 | 2.33 | 2.34 | < 0.02 | < 0.02 | 88.02 |
| 2022 | 2000.6 | < 0.02 | < 0.02 | 33.61 | 2.33 | 2.33 | < 0.02 | < 0.02 | 88.09 |
| 2033 | 2000.7 | < 0.02 | < 0.02 | 33.64 | 2.33 | 2.33 | < 0.02 | < 0.02 | 88.08 |
| 2008 | 2000.7 | 178.06 | 34.677 | 33.65 | 2.33 | 2.34 | < 0.02 | < 0.02 | 87.86 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72151 | Salinity (psu) |
| CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
| Conductivity CTD 23 - SN 2312 | Seabird | SBE4C | 2312 | |
| Fluorometer - CTD 23 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Fluorescence (arbitrary units) |
| Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 23-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
| Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 23 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
| Temperature CTD 23 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |