Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: CTD 20 - SN 0552,Conductivity CTD 20-SN 2235,Fluorometer - CTD 20 - WET Labs ECO FLNTU,Licor - CTD 20 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Scattering - CTD 20 - WET Labs ECO FLNTU,Temperature CTD 20 - SN 4522,Transmissometer - CTD 20 -CST-1421DR
When: 2016-04-02 08:16 to 2016-04-02 08:58 UTC
Where: 50° 24.8' S 147° 06.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Temperature (deg C) |
|---|---|---|
| 1224 | 3.2 | 7.23 |
| 1223 | 13.8 | 7.23 |
| 1222 | 28.6 | 7.23 |
| 1221 | 40.6 | 7.23 |
| 1220 | 58.2 | 7.10 |
| 1219 | 79.4 | 6.88 |
| 1218 | 99.5 | 5.95 |
| 1217 | 101.7 | 5.92 |
| 1216 | 123.4 | 5.32 |
| 1214 | 152.5 | 4.68 |
| 1215 | 152.5 | 4.68 |
| 1213 | 173 | 4.47 |
| 1212 | 198.4 | 4.10 |
| 1211 | 225.4 | 4.17 |
| 1210 | 251.4 | 4.25 |
| 1209 | 252.2 | 4.26 |
| 1208 | 277.8 | 3.83 |
| 1207 | 300.4 | 3.85 |
| 1206 | 325.2 | 4.01 |
| 1205 | 353.2 | 4.06 |
| 1204 | 401.8 | 4.16 |
| 1203 | 450.4 | 3.91 |
| 1201 | 500.8 | 3.71 |
| 1202 | 501.4 | 3.68 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Conductivity CTD 20-SN 2235 | Seabird | SBE-4 | 2235 | |
| Fluorometer - CTD 20 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
| Licor - CTD 20 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
| Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
| Scattering - CTD 20 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
| Temperature CTD 20 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
| Transmissometer - CTD 20 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |