Deployment Details
Survey: - IN2019_T02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 24 - SN 1332,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24 - SN 3198,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR
When: 2019-10-08 00:49 to 2019-10-08 02:04 UTC
Where: 15° 42.4' S 145° 51.6' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1224 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 24.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1222 | 5.1 | 214.02 | 35.246 | < 0.02 | 24.98 | 0.04 | < 0.02 | < 0.02 | 0.82 |
1223 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 24.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1221 | 38.8 | < 0.02 | < 0.02 | < 0.02 | 24.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1220 | 38.8 | < 0.02 | < 0.02 | < 0.02 | 24.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1219 | 39 | 214.55 | 35.256 | < 0.02 | 24.80 | 0.05 | < 0.02 | < 0.02 | 0.83 |
1216 | 76.3 | 214.51 | 35.281 | < 0.02 | 24.71 | 0.06 | < 0.02 | < 0.02 | 0.77 |
1218 | 76.5 | < 0.02 | < 0.02 | < 0.02 | 24.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1217 | 76.6 | < 0.02 | < 0.02 | < 0.02 | 24.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2114 | 151.6 | < 0.02 | < 0.02 | < 0.02 | 21.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1213 | 151.8 | 168.86 | 35.654 | 5.17 | 21.53 | 0.44 | < 0.02 | 0.05 | 1.40 |
1215 | 151.8 | < 0.02 | < 0.02 | < 0.02 | 21.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1211 | 250.5 | 171.14 | 35.420 | 9.47 | 16.92 | 0.73 | < 0.02 | < 0.02 | 3.13 |
1212 | 250.5 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1209 | 400.1 | 184.41 | 34.921 | 16.53 | 12.08 | 1.17 | < 0.02 | < 0.02 | 7.08 |
1210 | 400.2 | < 0.02 | < 0.02 | < 0.02 | 12.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 601 | 201.11 | 34.520 | 24.41 | 0.00 | 1.67 | < 0.02 | < 0.02 | 15.19 |
1208 | 601 | < 0.02 | < 0.02 | < 0.02 | 0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1206 | 800.5 | < 0.02 | < 0.02 | < 0.02 | 0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1205 | 800.9 | 194.41 | 34.434 | 28.71 | 0.00 | 1.97 | < 0.02 | < 0.02 | 28.05 |
1203 | 1000.3 | 182.53 | 34.444 | 31.42 | 0.00 | 2.16 | < 0.02 | < 0.02 | 43.53 |
1204 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1202 | 1308.1 | < 0.02 | < 0.02 | < 0.02 | 0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 1308.4 | 155.91 | 34.530 | 34.99 | 0.00 | 2.45 | < 0.02 | < 0.02 | 80.06 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 4835 | 1454 | Oxygen (µM) |
Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6302 | Seabird | SBE3T | 6302 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |