Deployment Details
Survey: - IN2019_T02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 24 - SN 1332,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70111,Optode Dissolved Oxygen Concentration,Oxygen CTD 24 - SN 3198,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Scattering - CTD 24 - WET Labs ECO FLNTU,Temperature CTD 24 - SN 6180,Temperature CTD 24 - SN 6302,Transmissometer - CTD 24 -CST-1421DR
When: 2019-10-06 23:55 to 2019-10-07 00:36 UTC
Where: 18° 41.9' S 148° 18.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1223 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1224 | 5 | < 0.02 | < 0.02 | < 0.02 | 25.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1222 | 5.1 | 213.26 | 35.216 | 0.03 | 25.02 | 0.07 | < 0.02 | < 0.02 | 0.62 |
1219 | 40.2 | 213.61 | 35.217 | 0.02 | 24.93 | 0.07 | < 0.02 | < 0.02 | 0.63 |
1221 | 40.4 | < 0.02 | < 0.02 | < 0.02 | 24.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1220 | 40.8 | < 0.02 | < 0.02 | < 0.02 | 24.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1218 | 79.6 | < 0.02 | < 0.02 | < 0.02 | 24.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1216 | 79.8 | 215.22 | 35.337 | 0.02 | 24.13 | 0.07 | < 0.02 | < 0.02 | 0.78 |
1217 | 80 | < 0.02 | < 0.02 | < 0.02 | 24.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2114 | 102.1 | 208.97 | 35.348 | 0.32 | 23.90 | 0.10 | 0.06 | 0.07 | 0.77 |
1215 | 102.2 | < 0.02 | < 0.02 | < 0.02 | 23.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 150.1 | 161.72 | 35.704 | 6.29 | 20.83 | 0.53 | < 0.02 | < 0.02 | 1.52 |
1213 | 150.4 | < 0.02 | < 0.02 | < 0.02 | 20.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1210 | 199.6 | 167.30 | 35.542 | 8.09 | 18.35 | 0.65 | < 0.02 | < 0.02 | 2.38 |
1211 | 199.9 | < 0.02 | < 0.02 | < 0.02 | 18.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1209 | 249.1 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1208 | 249.1 | 170.56 | 35.470 | 8.69 | 17.52 | 0.69 | < 0.02 | < 0.02 | 2.72 |
1207 | 300.3 | < 0.02 | < 0.02 | < 0.02 | 15.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1206 | 300.8 | 175.61 | 35.268 | 11.31 | 15.55 | 0.86 | < 0.02 | < 0.02 | 4.17 |
1204 | 350.3 | 179.89 | 35.119 | 13.15 | 13.96 | 0.96 | < 0.02 | < 0.02 | 5.06 |
1205 | 350.5 | < 0.02 | < 0.02 | < 0.02 | 13.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1202 | 424.8 | < 0.02 | < 0.02 | < 0.02 | 12.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 425.5 | 182.71 | 34.994 | 15.23 | 12.76 | 1.09 | < 0.02 | < 0.02 | 6.26 |
1203 | 425.5 | < 0.02 | < 0.02 | < 0.02 | 12.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Optode Dissolved Oxygen Concentration | Aanderaa | 4835 | 1454 | Oxygen (µM) |
Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Scattering - CTD 24 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Temperature CTD 24 - SN 6302 | Seabird | SBE3T | 6302 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |