Deployment Details
Survey: - IN2017_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4425,Licor - CTD 23 - SN 70111,Oxygen CTD 23 - SN 1794,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1735DR
When: 2017-03-25 16:11 to 2017-03-25 19:28 UTC
Where: 46° 04.4' S 142° 12.6' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.4 | < 0.02 | < 0.02 | 7.58 | 12.09 | 0.65 | 0.06 | 0.15 | 0.28 |
35 | 23.4 | < 0.02 | < 0.02 | 8.72 | 11.70 | 0.72 | 0.13 | 0.16 | 0.28 |
34 | 49.9 | 265.20 | 34.699 | 9.65 | 11.78 | 0.78 | 0.20 | 0.27 | 1.10 |
33 | 76.1 | < 0.02 | < 0.02 | 12.14 | 10.46 | 0.95 | 0.42 | 0.33 | 1.65 |
32 | 99.4 | < 0.02 | < 0.02 | 12.90 | 10.22 | 0.97 | 0.03 | 0.70 | 1.94 |
31 | 124.8 | 267.07 | 34.698 | 13.90 | 9.76 | 1.02 | 0.06 | 0.03 | 3.62 |
30 | 150.8 | < 0.02 | < 0.02 | 13.98 | 9.66 | 1.03 | < 0.02 | 0.03 | 3.86 |
29 | 170.8 | < 0.02 | < 0.02 | 14.16 | 9.51 | 1.04 | < 0.02 | 0.03 | 3.90 |
28 | 199 | 270.87 | 34.663 | 14.28 | 9.38 | 1.04 | < 0.02 | 0.03 | 3.81 |
27 | 224.3 | < 0.02 | < 0.02 | 14.38 | 9.25 | 1.05 | < 0.02 | 0.02 | 3.83 |
26 | 250.6 | < 0.02 | < 0.02 | 14.43 | 9.20 | 1.06 | < 0.02 | 0.02 | 3.78 |
25 | 299.5 | 273.37 | 34.625 | 14.64 | 9.11 | 1.07 | < 0.02 | 0.02 | 3.80 |
24 | 349.6 | < 0.02 | < 0.02 | 14.80 | 9.06 | 1.08 | < 0.02 | 0.02 | 3.86 |
23 | 401.2 | < 0.02 | < 0.02 | 14.85 | 9.05 | 1.08 | < 0.02 | 0.02 | 3.88 |
22 | 599 | 262.43 | 34.524 | 17.99 | 8.39 | 1.27 | < 0.02 | < 0.02 | 5.56 |
21 | 801 | < 0.02 | < 0.02 | 24.71 | 7.07 | 1.69 | < 0.02 | < 0.02 | 13.43 |
20 | 998.9 | < 0.02 | < 0.02 | 29.68 | 5.09 | 2.03 | < 0.02 | < 0.02 | 25.26 |
19 | 1199.8 | 202.27 | 34.354 | 32.75 | 3.95 | 2.25 | < 0.02 | < 0.02 | 41.82 |
18 | 1300.3 | < 0.02 | < 0.02 | 33.78 | 3.52 | 2.33 | < 0.02 | < 0.02 | 48.84 |
17 | 1401.3 | < 0.02 | < 0.02 | 34.45 | 3.27 | 2.38 | < 0.02 | < 0.02 | 56.89 |
16 | 1500.3 | 180.07 | 34.480 | 34.80 | 3.05 | 2.41 | < 0.02 | < 0.02 | 64.02 |
15 | 1600.7 | < 0.02 | < 0.02 | 34.88 | 2.97 | 2.43 | < 0.02 | < 0.02 | 73.95 |
14 | 1801.8 | < 0.02 | < 0.02 | 34.36 | 2.66 | 2.39 | < 0.02 | < 0.02 | 77.20 |
13 | 1999.9 | 176.01 | 34.656 | 33.73 | 2.49 | 2.34 | < 0.02 | < 0.02 | 82.73 |
12 | 2201 | < 0.02 | < 0.02 | 33.09 | 2.33 | 2.31 | < 0.02 | < 0.02 | 88.38 |
11 | 2401.3 | < 0.02 | < 0.02 | 32.88 | 2.21 | 2.29 | < 0.02 | < 0.02 | 93.69 |
10 | 2598.8 | 184.67 | 34.731 | 32.73 | 2.06 | 2.28 | < 0.02 | < 0.02 | 98.97 |
9 | 2798.7 | < 0.02 | < 0.02 | 32.69 | 1.92 | 2.28 | < 0.02 | < 0.02 | 103.32 |
8 | 2999.9 | < 0.02 | < 0.02 | 32.60 | 1.77 | 2.27 | < 0.02 | < 0.02 | 107.19 |
7 | 3200.4 | 195.21 | 34.734 | 32.58 | 1.62 | 2.27 | < 0.02 | < 0.02 | 110.39 |
6 | 3601.2 | < 0.02 | < 0.02 | 32.64 | 1.39 | 2.27 | < 0.02 | < 0.02 | 115.97 |
5 | 3800.1 | < 0.02 | < 0.02 | 32.71 | 1.29 | 2.28 | < 0.02 | < 0.02 | 118.30 |
4 | 3999.6 | 206.02 | 34.712 | 32.80 | 1.19 | 2.28 | < 0.02 | < 0.02 | 120.58 |
3 | 4200.3 | < 0.02 | < 0.02 | 32.98 | 1.08 | 2.29 | < 0.02 | < 0.02 | 122.91 |
2 | 4297.1 | < 0.02 | < 0.02 | 33.03 | 1.06 | 2.29 | < 0.02 | < 0.02 | 123.24 |
1 | 4628.4 | 208.12 | 34.712 | 33.04 | 1.08 | 2.30 | < 0.02 | < 0.02 | 124.06 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4425 | Seabird | SBE-4C | 4425 | |
Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 1794 | Seabird | SBE43 | 1794 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |