Deployment Details
Survey: - IN2017_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4425,Licor - CTD 23 - SN 70111,Oxygen CTD 23 - SN 1794,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1735DR
When: 2017-03-24 02:35 to 2017-03-24 05:39 UTC
Where: 46° 05.1' S 142° 15.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 6.2 | < 0.02 | < 0.02 | 9.62 | 11.54 | 0.74 | 0.04 | 0.18 | 0.08 |
35 | 24.6 | < 0.02 | < 0.02 | 9.88 | 11.45 | 0.75 | 0.06 | 0.19 | 0.13 |
34 | 49.8 | 281.59 | 34.484 | 11.09 | 11.11 | 0.84 | 0.27 | 0.21 | 0.74 |
33 | 74.7 | < 0.02 | < 0.02 | 10.94 | 11.17 | 0.85 | 0.43 | 0.28 | 1.11 |
32 | 100 | < 0.02 | < 0.02 | 13.04 | 10.14 | 0.96 | 0.27 | 0.46 | 1.71 |
31 | 125.9 | 268.64 | 34.664 | 14.25 | 9.59 | 1.01 | < 0.02 | 0.02 | 3.36 |
30 | 150 | < 0.02 | < 0.02 | 14.39 | 9.47 | 1.02 | < 0.02 | 0.02 | 3.54 |
29 | 171.6 | < 0.02 | < 0.02 | 14.48 | 9.35 | 1.03 | < 0.02 | 0.02 | 3.66 |
28 | 200.5 | 271.85 | 34.644 | 14.57 | 9.26 | 1.03 | < 0.02 | 0.02 | 3.61 |
27 | 222.3 | < 0.02 | < 0.02 | 14.60 | 9.21 | 1.04 | < 0.02 | 0.02 | 3.63 |
26 | 246.6 | < 0.02 | < 0.02 | 14.68 | 9.15 | 1.04 | < 0.02 | 0.02 | 3.58 |
25 | 299.4 | 273.73 | 34.625 | 14.70 | 9.11 | 1.04 | < 0.02 | 0.02 | 3.59 |
24 | 351.1 | < 0.02 | < 0.02 | 14.71 | 9.07 | 1.05 | < 0.02 | 0.02 | 3.57 |
23 | 401.7 | < 0.02 | < 0.02 | 14.91 | 9.06 | 1.06 | < 0.02 | 0.02 | 3.63 |
22 | 600.9 | 263.63 | 34.516 | 18.01 | 8.36 | 1.25 | < 0.02 | < 0.02 | 5.33 |
21 | 801 | < 0.02 | < 0.02 | 24.76 | 7.09 | 1.66 | < 0.02 | < 0.02 | 13.13 |
20 | 999.5 | < 0.02 | < 0.02 | 29.85 | 5.16 | 2.01 | < 0.02 | < 0.02 | 25.67 |
19 | 1200.3 | 202.98 | 34.353 | 32.82 | 3.97 | 2.23 | < 0.02 | < 0.02 | 41.11 |
18 | 1300.3 | < 0.02 | < 0.02 | 33.90 | 3.54 | 2.31 | < 0.02 | < 0.02 | 49.04 |
17 | 1399 | < 0.02 | < 0.02 | 34.64 | 3.25 | 2.37 | < 0.02 | < 0.02 | 56.62 |
16 | 1499.3 | 180.52 | 34.475 | 35.05 | 3.04 | 2.39 | < 0.02 | < 0.02 | 63.29 |
15 | 1600.4 | < 0.02 | < 0.02 | 35.15 | 2.97 | 2.41 | < 0.02 | < 0.02 | 73.94 |
14 | 1800.5 | < 0.02 | < 0.02 | 34.75 | 2.67 | 2.38 | < 0.02 | < 0.02 | 79.19 |
13 | 1998.8 | 176.23 | 34.660 | 33.95 | 2.47 | 2.33 | < 0.02 | < 0.02 | 83.26 |
12 | 2200.2 | < 0.02 | < 0.02 | 33.38 | 2.33 | 2.29 | < 0.02 | < 0.02 | 88.43 |
11 | 2399.7 | < 0.02 | < 0.02 | 33.10 | 2.20 | 2.27 | < 0.02 | < 0.02 | 94.07 |
10 | 2599.9 | 184.27 | 34.731 | 32.99 | 2.07 | 2.27 | < 0.02 | < 0.02 | 99.11 |
9 | 2799.6 | < 0.02 | < 0.02 | 32.93 | 1.91 | 2.26 | < 0.02 | < 0.02 | 103.74 |
8 | 2999.6 | < 0.02 | < 0.02 | 32.87 | 1.76 | 2.26 | < 0.02 | < 0.02 | 107.30 |
7 | 3199.7 | 194.59 | 34.733 | 32.87 | 1.63 | 2.26 | < 0.02 | < 0.02 | 110.87 |
6 | 3600 | < 0.02 | < 0.02 | 32.86 | 1.41 | 2.25 | < 0.02 | < 0.02 | 115.41 |
5 | 3898.7 | < 0.02 | < 0.02 | 32.99 | 1.27 | 2.26 | < 0.02 | < 0.02 | 119.07 |
4 | 3999.6 | 205.57 | 34.719 | 33.07 | 1.20 | 2.26 | < 0.02 | < 0.02 | 120.26 |
3 | 4098.5 | < 0.02 | < 0.02 | 33.15 | 1.13 | 2.27 | < 0.02 | < 0.02 | 121.94 |
2 | 4399.2 | < 0.02 | < 0.02 | 33.28 | 1.07 | 2.28 | < 0.02 | < 0.02 | 124.00 |
1 | 4707.9 | 208.21 | 34.712 | 33.31 | 1.09 | 2.28 | < 0.02 | < 0.02 | 124.31 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4425 | Seabird | SBE-4C | 4425 | |
Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 1794 | Seabird | SBE43 | 1794 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |