Deployment Details
Survey: - IN2017_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4425,Licor - CTD 23 - SN 70111,Oxygen CTD 23 - SN 1794,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1735DR
When: 2017-03-22 14:18 to 2017-03-22 17:43 UTC
Where: 46° 00.8' S 142° 00.3' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.3 | 278.37 | < 0.02 | 6.59 | 12.61 | 0.56 | 0.12 | 0.14 | 0.18 |
35 | 26.1 | < 0.02 | < 0.02 | 6.59 | 12.62 | 0.58 | 0.35 | 0.14 | 0.20 |
34 | 50.4 | 278.68 | 34.611 | 7.87 | 12.23 | 0.65 | 0.32 | 0.14 | 0.34 |
33 | 74.6 | 268.14 | < 0.02 | 9.77 | 11.41 | 0.78 | 0.51 | 0.22 | 0.97 |
32 | 100.2 | < 0.02 | < 0.02 | 10.18 | 12.25 | 0.75 | < 0.02 | 0.04 | 2.50 |
31 | 125.5 | 240.72 | 34.977 | 11.81 | 11.63 | 0.85 | < 0.02 | 0.02 | 2.99 |
30 | 150.9 | 242.11 | < 0.02 | 13.46 | 10.93 | 0.95 | < 0.02 | 0.02 | 3.88 |
29 | 170.3 | < 0.02 | < 0.02 | 14.11 | 9.78 | 1.00 | < 0.02 | 0.02 | 3.47 |
28 | 200.2 | < 0.02 | 34.659 | 14.47 | 9.41 | 1.03 | < 0.02 | 0.02 | 3.65 |
27 | 223.3 | 272.39 | < 0.02 | 14.66 | 9.22 | 1.04 | < 0.02 | 0.02 | 3.72 |
26 | 250.7 | < 0.02 | < 0.02 | 14.79 | 9.15 | 1.05 | < 0.02 | 0.02 | 3.74 |
25 | 298.1 | 273.37 | 34.616 | 14.96 | 9.07 | 1.06 | < 0.02 | 0.02 | 3.83 |
24 | 349.3 | < 0.02 | < 0.02 | 15.13 | 8.98 | 1.07 | < 0.02 | 0.02 | 3.82 |
23 | 398.7 | 272.61 | < 0.02 | 15.40 | 8.94 | 1.09 | < 0.02 | 0.02 | 3.92 |
22 | 599.9 | < 0.02 | 34.526 | 18.31 | 8.38 | 1.27 | < 0.02 | < 0.02 | 5.67 |
21 | 799.1 | 221.83 | < 0.02 | 25.16 | 6.98 | 1.69 | < 0.02 | < 0.02 | 14.21 |
20 | 1000 | < 0.02 | < 0.02 | 29.32 | 5.37 | 1.97 | < 0.02 | < 0.02 | 23.55 |
19 | 1199.1 | < 0.02 | 34.351 | 32.50 | 4.13 | 2.21 | < 0.02 | < 0.02 | 39.53 |
18 | 1299.7 | < 0.02 | < 0.02 | 33.59 | 3.79 | 2.29 | < 0.02 | < 0.02 | 49.51 |
17 | 1399.8 | 184.85 | < 0.02 | 34.52 | 3.39 | 2.36 | < 0.02 | < 0.02 | 58.06 |
16 | 1501.4 | < 0.02 | 34.477 | 34.96 | 3.16 | 2.39 | < 0.02 | < 0.02 | 64.74 |
15 | 1601.4 | 173.20 | < 0.02 | 35.13 | 3.02 | 2.41 | < 0.02 | < 0.02 | 71.51 |
14 | 1800.8 | < 0.02 | < 0.02 | 34.69 | 2.67 | 2.37 | < 0.02 | < 0.02 | 77.40 |
13 | 1999.9 | 176.81 | 34.659 | 33.92 | 2.48 | 2.32 | < 0.02 | < 0.02 | 82.29 |
12 | 2198 | < 0.02 | < 0.02 | 33.39 | 2.33 | 2.29 | < 0.02 | < 0.02 | 88.60 |
11 | 2399.3 | < 0.02 | < 0.02 | 33.11 | 2.20 | 2.28 | < 0.02 | < 0.02 | 94.27 |
10 | 2599.1 | 184.63 | 34.732 | 32.96 | 2.05 | 2.27 | < 0.02 | < 0.02 | 100.02 |
9 | 2799.9 | < 0.02 | < 0.02 | 32.93 | 1.90 | 2.27 | < 0.02 | < 0.02 | 104.12 |
8 | 3001.5 | < 0.02 | < 0.02 | 32.82 | 1.77 | 2.26 | < 0.02 | < 0.02 | 107.29 |
7 | 3100.9 | 193.16 | 34.734 | 32.90 | 1.68 | 2.26 | < 0.02 | < 0.02 | 109.69 |
6 | 3301.1 | < 0.02 | < 0.02 | 32.73 | 1.56 | 2.24 | < 0.02 | < 0.02 | 111.28 |
5 | 3501.1 | < 0.02 | < 0.02 | 32.82 | 1.46 | 2.25 | < 0.02 | < 0.02 | 114.15 |
4 | 3701 | 202.49 | 34.726 | 32.83 | 1.36 | 2.25 | < 0.02 | < 0.02 | 116.29 |
3 | 3901.1 | < 0.02 | < 0.02 | 32.93 | 1.26 | 2.26 | < 0.02 | < 0.02 | 119.59 |
2 | 4000.4 | < 0.02 | < 0.02 | 33.05 | 1.19 | 2.26 | < 0.02 | < 0.02 | 120.82 |
1 | 4205.7 | 207.85 | 34.713 | 33.20 | 1.07 | 2.27 | < 0.02 | < 0.02 | 123.55 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4425 | Seabird | SBE-4C | 4425 | |
Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 1794 | Seabird | SBE43 | 1794 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |